17
OM-405
4.5
Installing Exhaust Pipe
ST-801 681 / Ref. ST-183 175-A
Point exhaust pipe in desired
direction. If unit is truck or trailer
mounted, point pipe away from
direction of travel.
Tools Needed:
1/2 in
4.6
Connecting to Weld Output Terminals
ST-800 396-A / Ref. ST-183 175-A
1
Work Weld Output Terminal
2
Electrode Weld Output
Terminal
Connect work cable to Work
terminal.
Connect electrode holder cable or
electrode weld cable to Electrode
terminal for Stick and MIG welding.
Connect torch cable to Electrode
terminal for TIG welding.
Use Process Selector switch to
select type of weld output (see
Section 5.1).
1
Tools Needed:
3/4 in
2
4.7
Selecting Weld Cable Sizes
Total Cable (Copper) Length in Weld Circuit Not Exceeding
Welding
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Amperes
10 – 60%
Duty Cycle
60 – 100%
Duty Cycle
10 – 100% Duty Cycle
100
4
4
4
3
2
1
1/0
1/0
150
3
3
2
1
1/0
2/0
3/0
3/0
200
3
2
1
1/0
2/0
3/0
4/0
4/0
250
2
1
1/0
2/0
3/0
4/0
2-2/0
2-2/0
300
1
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
350
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
S-0007-D
Содержание Bobcat 225 NT
Страница 4: ......
Страница 39: ...35 OM 405 10 Electrical Diagrams 10 1 Circuit Diagram For Welding Generator Onan Powered Units SB 180 688...
Страница 40: ...36 OM 405 10 2 Circuit Diagram For Welding Generator Kohler Powered Units SB 183 459 A...
Страница 65: ...61 OM 405 Notes...
Страница 70: ...Notes...
Страница 71: ...Notes...
Страница 72: ...Notes...