7. Maintenance (Onan-Powered Units)
7.1
Routine Maintenance (Onan-Powered Units)
Recycle engine
fluids.
Stop engine before maintaining.
See also Engine Manual and maintenance
label. Service engine more often if used in
severe conditions.
8 h
20 h
Wipe up spills.
Check fluid levels.
See Section 4.2.
Check and clean spark
arrestor screen. See
Section 7.7.
50 h
25 h
Clean and
tighten weld
terminals.
Clean cooling system.
See Engine Manual.
Service air
cleaner wrapper
(foam element).
See Section 7.3.
100 h
Change oil. See
Section 7.5 and
maintenance label.
Change oil filter. See
Section 7.5 and
maintenance label.
Clean and
tighten battery
connections.
Service air
cleaner element.
See Section 7.3.
200 h
Replace fuel filter.
See Section 7.5.
Check valve
clearance.
Check spark
plugs.
Replace unreadable
labels.
500 h
Repair or
replace cracked
cables.
1000 h
Blow out or
vacuum inside.
During heavy
service, clean
monthly.
OR
Clean crankcase
breather valve.
Remove cylinder
head deposits.