8-7. Overload Protection
803 605
2
1
7
8
6
3
!
Stop engine.
When a supplementary protector, cir-
cuit breaker or fuse opens, it usually
indicates a more serious problem ex-
ists. Contact Factory Authorized Ser-
vice Agent.
1
Fuse F1
2
Fuse F2
F1 and F2 protect the stator exciter wind-
ing from overload. If F1 opens, weld and
generator power is low or stops entirely. If
F2 opens, weld output is low or stops en-
tirely. 4 kVA/kW generator power is still
available.
3
Supplementary Protector CB9
4
Supplementary Protector CB29
5
Circuit Breaker CB10 (Not Shown)
6
Supplementary Protector CB2
7
Supplementary Protector CB3
8
Supplementary Protector CB4
9
Circuit Breaker CB14 (Not Shown)
CB9 and CB29 protect the 24 volt AC out-
put to remote receptacles, and 24 volt out-
put to field current regulator board PC?. If
CB opens, weld output and 24 volt output
to remote receptacle stops.
CB10 protects the engine battery circuit. If
CB10 opens, the engine will not crank.
CB10 automatically resets when the fault
is corrected.
CB2 protects the engine control circuit. If
CB2 opens, the engine does not crank.
CB3 protects the engine weld control cir-
cuit. If CB3 opens, weld output stops,
meters will be blank; however, generator
power is still available.
CB4 protects the field flashing circuit. If
CB4 opens, the generator may not excite
at start-up and weld and generator power
output may not be available.
CB14 protects throttle solenoid TS1. If
CB14 opens, the engine does not run at
idle speed. CB14 automatically resets
when the fault is corrected.
Press button to reset.
4
Содержание big blue 700 duo pro
Страница 51: ...OM 252 624 Page 47 6 8 Fuel Hour Gauge Descriptions...
Страница 66: ...OM 252 624 Page 62 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Export Welding Generator...
Страница 67: ...OM 252 624 Page 63 250 340 E...
Страница 68: ...OM 252 624 Page 64 Figure 9 2 Circuit Diagram For North American Welding Generator...
Страница 69: ...OM 252 624 Page 65 249 603 D...