OM-252 624 Page 53
8-3. Checking Generator Brushes
GenBrush1 2012
−
05 / Ref 190 823
!
Stop engine and let cool.
1
Generator Brush
Mark and disconnect leads at brush hold-
er cap. Remove brushes.
Replace brushes if damaged or if brush
material is at or near minimum length.
1
Damaged Brushes
New Length:
1-1/4 in. (32 mm)
Minimum Length:
5/8 in. (16 mm)
Replace
Notes
Содержание big blue 700 duo pro
Страница 51: ...OM 252 624 Page 47 6 8 Fuel Hour Gauge Descriptions...
Страница 66: ...OM 252 624 Page 62 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Export Welding Generator...
Страница 67: ...OM 252 624 Page 63 250 340 E...
Страница 68: ...OM 252 624 Page 64 Figure 9 2 Circuit Diagram For North American Welding Generator...
Страница 69: ...OM 252 624 Page 65 249 603 D...