OM-252 624 Page 45
6-6. Remote Voltage/Amperage Control
1
Remote 14 Receptacle
Connect optional remote control to receptacle
(see Section 5-17).
When a remote control is connected to the
Remote receptacle, the Auto Sense Re-
mote feature automatically switches volt-
age/amperage control to the remote con-
trol. When a device is connected to the Re-
mote receptacle, remote voltage/amper-
age control is always available regardless
of the position of the Process/Contactor
switch.
2
Voltmeter
3
Ammeter
0774 / Ref.246 345-B / Ref. 907 428
−
1
Turn Remote Control On. Ad-
just Optional Remote
Control to 100%
Set V/A Control
To Desired Maximum
Weld Output Using Weld
Meters
Set TIG or STICK Process
In Example:
Min = 20 A DC
Max = 205 A DC
Max (205 A DC)
Min (20 A DC)
Connect Remote
Control To Remote
Receptacle RC14
Adjust Optional Remote
Control to desired
weld output
Ammeter Shows Preset
Output When Not Welding,
Actual Amperage While
Welding
Set WIRE Process
Connect Remote
Control To Remote
Receptacle RC14
Adjust Optional Remote
Control to desired
weld output
1
2 3
CC Welding
CV Welding
85
205
Voltmeter Shows Open-Circuit
Voltage When Not Welding, Arc
Voltage While Welding
Voltmeter Toggles Between
Preset And Actual Output
When Not Welding, Actual
Voltage While Welding
28
0
Ammeter Shows Zero
Содержание big blue 700 duo pro
Страница 51: ...OM 252 624 Page 47 6 8 Fuel Hour Gauge Descriptions...
Страница 66: ...OM 252 624 Page 62 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Export Welding Generator...
Страница 67: ...OM 252 624 Page 63 250 340 E...
Страница 68: ...OM 252 624 Page 64 Figure 9 2 Circuit Diagram For North American Welding Generator...
Страница 69: ...OM 252 624 Page 65 249 603 D...