OM-223 426 Page 14
3-6. Plug Connections
804 104-C
1
Weld Control
2
Motor Control Cord (Not
Supplied)
Cord is available in 20 ft (6.1 m),
30 ft (9.1 m) or 50 ft (15.2 m)
lengths.
3
Motor/Drive Assembly
To make connections, align key-
way, insert plug, and tighten
threaded collar.
1
2
3
3-7. Threading And Feeding Welding Wire
Ref. 804 391-A / Ref. 156 798 / 802 914
Tools Needed:
POWER
PURGE
6 in
(150 mm)
Hold wire tightly to keep it
from unraveling.
V
Turn on power at welding power source.
Pull and hold wire; cut off end.
ON
OFF
JOG
Welding Power Source
WOOD
Press Jog push button until wire comes
out of gun. Feed wire to check drive roll
pressure. Adjust knob enough to pre-
vent slipping.
Cut off wire. Close cover.
Push wire thru guide up to drive rolls; continue to
hold welding wire. Press power source Jog push
button until drive rolls grab wire. Adjust tension until
wire does not slip. Indicator is for reference only.
JOG
Pressure
Adjust
Pressure
Adjust
Содержание AA40GB w/OCP