A complete Parts List is available at www.MillerWelds.com
OM-257220 Page 36
8-5.
Typical Connection For Voltage-Sensing Feeder GMAW/FCAW Process
277780-A
!
Turn off power before making con-
nections.
1
Positive (+) Weld Output Terminal
2
Negative (−) Weld Output Terminal
3
Ground Cable to Workpiece
4
Workpiece
5
Voltage Sensing Clamp
6
Gun
7
Gun Trigger Receptacle
8
Wire Feeder
9
Gas Hose
10 Gas Cylinder
Use of shielding gas is dependant on Wire
Type.
.
The connection diagram illustrates
DCEP (reverse polarity) suitable for all
wires except self-shielded FCAW. The
majority of self-shielded FCAW wires
require DCEN (straight polarity).
2
3
9
10
8
7
5
6
4
1
Содержание 907525
Страница 51: ...A complete Parts List is available at www MillerWelds com OM 257220 Page 45 Notes...
Страница 52: ...OM 257220 Page 46 SECTION 11 ELECTRICAL DIAGRAM Figure 11 1 Circuit Diagram...
Страница 53: ...OM 257220 Page 47 256 909 B...
Страница 54: ...Notes...