OM-252 203 Page 14
B. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
The EMF assessment on this equipment was conducted at 0.5 meter.
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
C. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
ce-emc 3 2014-07
SECTION 5 − INSTALLATION
5-1.
Equipment Connection Diagram
Ref. 256 615-A
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
!
Do not move or operate
equipment where it could
tip.
!
Use only with CC/CV DC
Power Sources.
1
Constant Current (CC) or
Constant Voltage (CV)
Welding Power Supply
2
Weld Cable To Feeder
3
Work Cable To Workpiece
Weld cable and work cable connec-
tions to power source (DCEN/
DCEP) are dependant on wire type.
Since feeder is not polarity sen-
sitive, there is no need for an
electrode polarity switch.
4
Workpiece
5
Voltage Sensing Clamp
Connect voltage sensing clamp to
workpiece.
6
Gun
7
Gun Trigger Receptacle
8
Wire Feeder
9
Gas Hose
10 Gas Cylinder
Use of shielding gas is dependant
on wire type.
Shielding gas pressure not to
exceed 100 psi (689 kPa).
1
2
3
4
8
9
10
6
7
5
Содержание SuitCase X-TREME 12VS
Страница 14: ...OM 252 203 Page 10...
Страница 28: ...OM 252 203 Page 24 6 4 Wire Speed Control Settings Ref 257 488 A Notes...
Страница 33: ...OM 252 203 Page 29 SECTION 8 ELECTRICAL DIAGRAM 252 200 D Figure 8 1 Circuit Diagram For Wire Feeder...
Страница 42: ...Notes...