OM-221 022 Page 13
Light Flashing = Active Feature
Lights Indicate Which Selection Is Active
Light On = Selected Option Of Feature 1 Or 2
Press & Hold To Scroll Between Features.
Release At Desired Feature.
To Change
Trigger Method
To Change
Pulse Frequency (PPS)
Press and release switch pad to
see active Trigger Method. Continue
to press and release switch pad to
change Trigger Method.
Press and release switch pad to
see active Pulse Frequency. Continue
to press and release switch pad to
change Pulse Frequency.
NOTE: If no action is taken within 5 seconds,
the light for Feature 1 begins to flash, and
last Trigger Method selected remains active.
NOTE: If no action is taken within 5 seconds,
the light for Feature 2 begins to flash, and last
Pulse Frequency selected remains active.
Lift Arc panel
control
2.5 PPS
2T Trigger Hold
See below
60 PPS
.5 PPS
Standard
To save changes and exit
set-up mode, press and
release torch trigger, or
turn power off and wait
until lights turn off, and
then turn power back on.
1 PPS
3. Self-Holding Feature
1. Preflow
0.2 Seconds Preset
2. Upslope
Main Arc Start
In 0 Seconds
4. Down Slope
30 Amps, 0.75 Seconds
80 Amps, 2.0 Seconds
120 Amps, 3.0 Seconds
Final 0 Amps
5. After Flow
10 Amps, 1 Second
100 Amps, 10 Seconds
2T Trigger Hold Sequence