OM-4423 Page 28
6-5. Remote Voltage/Amperage Control
1
Remote 14 Receptacle RC14
Connect optional remote control to RC14 (see
Section 5-9).
When a remote control is connected to the
Remote receptacle, the Auto Sense Re-
mote feature automatically switches volt-
age/amperage control to the remote con-
trol. When a device is connected to the Re-
mote receptacle, remote voltage/amper-
age control is always available regardless
of the position of the Process/Contactor
switch.
0774 / Ref. 217 358-B / Ref. 803 576
−
C
Adjust Optional Remote Control
Set V/A Control
To Desired Maximum
Weld Output Using Weld
Meters
Set TIG or STICK Process
Adjust Optional Remote
Control To Desired Weld
Output
In Example:
Process = Remote Stick
Min = 20 A DC
Max = 205 A DC
Max (205 A DC)
Min (20 A DC)
Connect Remote
Control To Remote
Receptacle RC14
Connect Remote
Control To Remote
Receptacle RC14
Set WIRE Process
1
Adjust Optional Remote
Control to 100%
Weld meters will always
show the combined main and
remote control setting and
machine welds at nominal
output settings of the meter.
Weld meters show preset
output when not welding.