OM-4423 Page 23
5-9. Connecting To Remote 14 Receptacle RC14
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by circuit
breaker CB8.
24 VOLTS AC
B
Contact closure to A completes
24 volt ac contactor control
circuit.
C
Output to remote c10
volts dc in MIG mode; 0 to +10
volts dc in Stick or TIG mode.
REMOTE
OUTPUT
D
Remote control circuit common.
OUTPUT
CONTROL
E
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
F
Current feedback: 1 volt per
100 amperes.
OR
H
Voltage feedback: 1 volt per 10
arc volts.
GND
K
Chassis common.
Ref 803 576
−
C
NEUTRAL
G
Circuit common for 24 and 115
volt ac circuit.
*The remaining sockets are not used.