2-1. Disconnect primary power to the operator.
2-2. Leave enough slack in your wiring to allow removal of MIM-62 if/when re-learning is required.
2-3. Prepare a mounting location for MIM-62 inside the operator. Use the two mounting slots on the
top cover of MIM-62.
Note: Do not mount MIM-62 yet. The switches and the Learn button on the rear panel of MIM-62
must be accessed during installation.
2-4. Connect the power leads to the removable 8-pin connector, as indicated in Figure 1.
www.GateOpenerSafety.com
INPUTS 1-2
(top to bottom):
– Input
– Com
– Power-
– Power+
INPUTS 3-6
(top to bottom):
– Power+
– Power-
– Com
– Input
–
COM
–
P/N.C.
–
10K
–
COM
–
P/N.C.
–
10K
–
12-24 V
AC/DC
–
12-24 V
AC/DC
Outputs A & B connect to the
appropriate safety device’s
input (pulsed, N.C., 10K) on
your operator’s main board
Connect to your operator’s
accessory power supply
(12-24 VAC/DC).
Inputs 1 & 2 must be used.
They are assigned to Output
A. Inputs 3-6 can be assigned
to Output A or B.
Your monitored devices may*
be powered through the MIM-
62 for convenience or simply
utilize your operator’s power
supply outputs (12-24 VDC).
*Note: All N.C. devices must
be powered through MIM-62.
2-
Install Module & Test
Figure 1
P1