INSTALLATION
14
TECHNICAL DOCUMENTATION
INTERNAL CONTROLS BREAKDOWN (MAIN PCB)
[1]
Used to either power additional pump or motorised valve.
[2]
Only used on Burner #00.
[3]
Only used on Burner #01.
01 02 03
04 05 06
01 02 03 04 05
06 07 08 09 10
01 02
03 04
01
02
03
04
05
06
07
08
09
10
11
12
13
14
01
02
03
04
05
06
07
08
01
02
03
04
05
06
01
02
03
04
01
02
03
04
05
10
09
08
07
06
X18
F00
F01
X16
X17
X13
X12
X15
X14
X11
X02
X01
X00
▲
FIGURE 02.
TOP VIEW OF MAIN PCB.
• X14 Pin 01: Link to X14 Pin 05
[3]
• X14 Pin 02: Link to X14 Pin 06
[3]
• X14 Pin 05: Link to X14 Pin 01
[3]
• X14 Pin 06: Link to X14 Pin 02
[3]
• X15 Pin 01: Main PCB to Control Fascia
[2]
• X15 Pin 02: Main PCB to Control Fascia
• X15 Pin 03: Main PCB to Control Fascia
[2]
• X15 Pin 04: Main PCB to Control Fascia
• X15 Pin 05: Main PCB to Control Fascia
• X15 Pin 06: Main PCB to Control Fascia
• X02 Pin 01: Transformer
• X02 Pin 02: Transformer
• X02 Pin 05: Gas Valve Rectified
• X02 Pin 06: Gas Valve Rectified
• X11 Pin 01: AC Fan Interface
• X11 Pin 02: AC Fan Interface
• X11 Pin 03: Flap Valve
• X11 Pin 06: AC Fan Interface
• X11 Pin 07: AC Fan Interface
• X11 Pin 08: Flap Valve
• X13 Pin 01: Pressure Sensor
[2]
• X13 Pin 02: Pressure Sensor
[2]
• X13 Pin 04: DHW Sensor
• X13 Pin 05: Return Sensor
• X13 Pin 06: Supply Sensor
• X13 Pin 07: Flue Gas High Limit Switch
• X13 Pin 08: Pressure Sensor
[2]
• X13 Pin 11: DHW Sensor
• X13 Pin 12: Return Sensor
• X13 Pin 13: Supply Sensor
• X13 Pin 14: Flue Gas High Limit Switch
• X00 Pin 01: Power to Main PCB
• X00 Pin 02: Power to Main PCB
• X01 Pin 01: Boiler Run Signal
• X01 Pin 02: Pump
• X01 Pin 03: 240 V Output
[1][2]
• X01 Pin 04: 240 V Output
[1][2]
• X01 Pin 05: Fan Mains
• X01 Pin 07: Pump
• X01 Pin 08: 240 V Output
[1][2]
• X01 Pin 10: Fan Mains