background image

The DA-660 Reception Booster Antenna

 is perfect when monitoring remote buildings or equipment:

This antenna is used to increase the standard reception distance of 1000-feet, to up to 3/4-mile from the Sensor/Transmitter to the 

Control Panel/Receiver.  Simply unscrew the standard antenna on the DA-700 Control Panel or DA-100 Control Panel and 75ohm coaxial 

cable, RG6,  to the F Connectors on the Control Panel and the DA-660 Reception Booster Antenna.

* 34” Long, 13” Wide, 1” High and weighs approximately 1 pound

* Frequency = 433.92 mHz

* Impedance = 75 Ohms

* Gain = 10.6 dB

* Type = 7 Element Yagi

The DA-REPEATER is perfect for providing additional alerts in remote buildings

This Drive-Alert Signal Repeater can an be attached to any DA-700 or DA-500 Drive-Alert Control Panel/Receiver.  It will 

repeat the alert signal to other wireless Control Panel/Receivers (DA-100CP, DA-700CP,) up to an additonal 1000 feet away, or another 3/4-

mile if DA-660s are used with them.  If a site has multiple buildings and/or locations where an alert is desired, add a DA-REPEATER to a 

DA-700 Control Panel/Receiver, and then add DA-100CP Chimes with Volume Control (shown below) in those other buildings.

The DA-100CP Long Distance Remote Chime for adding chimes to remote buildings:

 

The DA-100CP is actually a self-contained Control Panel/Receiver on its own, and receives a signal from up to 1000-feet 

 

of any of Mier’s wireless Sensor/Transmitters, OR a DA-REPEATER (shown above), and provides a pleasant tone as an 

 

alert.  It also includes volume control.

The DA-611TO and DA-612TO Sensor/Transmitters increase transmission distance:

The Sensor(s) is/are outside the Transmitter Box, and attached to the Transmitter by a 50-foot cable (cable lengths up to 1000 feet are 

available).  This allows the sensor to be buried under or next to the driveway or area to be monitored, and the transmitter box to be 

hidden up to 50 feet away and 4 feet above ground for an increased transmitting range.  The sensor should be buried 6-12 inches below 

ground and the cable 6 inches below ground.  Mier HIGHLY RECOMMENDS burying the cable in 1/2-inch PVC pipe to protect it.  Try the 

Sensor and Transmitter above ground for a week, before burying the Sensor, to assure conditions and product operate satisfactorily.

Note: installation instructions come with these Sensor/Transmitters when ordered, or are available for download on our website.

   DA-611TO 

    DA-612TO

Please contact our Tech Support Team and we will be happy to “Google™earth” your installation site, and provide you with

information on the products needed, and locations for each piece to meet your installation/application goals.

Don’t forget to check out our website for cut-sheets, installation manuals, installation examples, and information on more products!

13

Four Options for Long Range Drive-Alert Installations

800-473-0213        ~        [email protected]        ~        www.mierproducts.com

Содержание Drive-Alert DA-700

Страница 1: ...tes alarm panels or other equipment 7 Add a repeater to send the signal another 1000 feet to trigger alerts in other buildings or add a DA 660 booster antenna for buildings up to 3 4 mile away 8 Monit...

Страница 2: ...ns page Use of an unlimited Wireless Sensor Transmitters DA 610TO DA 611TO DA 612TO with a DA 700 Control Panel Receiver Compatible with Mier Accessories detailed in this manual See Accessories Page a...

Страница 3: ...the first Transmitter on Zone 2 Pin for Zone 2 in the second and Zone 3 Pin for Zone 3 in the third The Control Panel will now respond with a different chime for each Zone Test by turning on one Sens...

Страница 4: ...directions Lightning strikes cause a large disturbance in the magnetic field so nearby strikes will cause an alarm It is also possible for electrical current variations in nearby power lines to cause...

Страница 5: ...the underside of the cover Failing to do these things will result in moisture entering the enclosure The Sensor Transmitter can now be placed in position For maximum range the black box Transmitter p...

Страница 6: ...mpers on the Zone Pins on the electrical board in the black box to active them AND pull the jumper off of the JP3 Jumper Pin inside the white DA 700 or DA 100 Control Panel The Drive Alert will give a...

Страница 7: ...he next page for instructions on setting the time and activating the Mute Delay as well as setting the Relay Timer for accessories The RL5 D12 LED red is on when the Control Panel Receiver detects a v...

Страница 8: ...ops flashing if you have depressed the Green Button 1 2 3 or 4 times your program is set Move the SW3 switch back to the Mute position to keep both the Timer and the Mute in ready mode so they can be...

Страница 9: ...ternal Mute Delay button is not convenient 16 Mute Delay Accessory Switch Input for Mute Delay Control if green internal Mute Delay button is not convenient 17 Gnd Ground or 24VDC or 12VDC 18 12DC 12V...

Страница 10: ...nel DA 066MP Wireless Chime Transmitter up to 100 ft 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 24 Gnd Z 1 Z 2 Z 3 Timer Relay All Det Relay Mute P B Gnd 12 Not 10 0 DC or Relay Relay Relay 4...

Страница 11: ...24 C NO C NO C NO NC C NO NC C NO 12 Batt Two Gray wires from the DA 606LK wireless light transmitter one goes to 13 terminal All Detect C Common and the other goes to terminal 14 All Detect NO Normal...

Страница 12: ...is used to hide the DA 610 Sensor HARD WIRED DRIVE ALERT ACCESSORIES DA 655 DA 500LKA DA 052V DA 505 DA 505W DA 050 The Hard Wired DA 655 Chime with Volume Control is our most popular accessory for t...

Страница 13: ...es a signal from up to 1000 feet of any of Mier s wireless Sensor Transmitters OR a DA REPEATER shown above and provides a pleasant tone as an alert It also includes volume control The DA 611TO and DA...

Страница 14: ...Microamp 12 Active Current 3 Milliamp 13 Battery Life One Year in residential installation but up to 5 years if using lithium batteries 14 Operating Temperature 40 DEGREES F TO 125 DEGREES F 15 Weight...

Страница 15: ...und this is above the non ferrous belt line Mount the Sensor securely IT MUST BE STABLE AND MOTIONLESS Any movement of the sensor will cause an alarm Don t mount the Sensor on a tree post or gate that...

Страница 16: ...20 apart OK Check that All Detect red LED RL5 D12 on in the Control Panel when a detection and transmission was to occur Note listen for a Relay click OK If using a long range reception antenna check...

Страница 17: ...rive Alert accessories and parts built by other OEMs including but not limited to chimes lamp modules light switches bells splice kits are covered under their respective OEM warranties This warranty c...

Страница 18: ...________________________________________________ Name Contact Information of where the Mier Products Drive Alert Equipment was purchased if different than Installation Company ________________________...

Страница 19: ...NOTES...

Страница 20: ......

Отзывы: