background image

Connecting a DA-REPEATER Wireless Alert Transmitter, for DA-100 and other Control 

Panels, to a DA-700 Control Panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

+24  Gnd    Z-1         Z-2         Z-3      Timer Relay  All Det Relay 

Mute P/B 

Gnd +12 

Not

  +10,0

 DC   or    Relay     Relay     Relay            4                    5           

(Remote)

   or   DC 

used  

Low

        -24    C   NO    C  NO    C  NO   NC  C   NO    NC  C   NO             -12                 Batt  

DA-REPEATER Wireless Transmitter 

(up to 1000 ft)

Connecting a Hard Wired DA-655 Chime

to a DA-700 Control Panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

+24  Gnd    Z-1         Z-2         Z-3      Timer Relay  All Det Relay 

Mute P/B 

Gnd +12 

Not

  +10,0

 DC   or    Relay     Relay     Relay            4                    5           

(Remote)

   or   DC 

used  

Low

        -24    C   NO    C  NO    C  NO   NC  C   NO    NC  C   NO             -12                 Batt  

DA-655 Hard-Wired Chime

with volume control

Connecting a DA-066MP Wireless Chime Transmitter, for DA-078 Chimes,

to a DA-700 Control Panel

DA-066MP Wireless Chime 

Transmitter (up to 100 ft)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

+24  Gnd    Z-1         Z-2         Z-3      Timer Relay  All Det Relay 

Mute P/B 

Gnd +12 

Not

  +10,0

 DC   or    Relay     Relay     Relay            4                    5           

(Remote)

   or   DC 

used  

Low

        -24    C   NO    C  NO    C  NO   NC  C   NO    NC  C   NO             -12                 Batt  

Red wire

 from DA-066MP to #1 te24DC.        Black wire from DA-066MP to #2 terminal/GND.        

Green wire

 from DA-066MP to 

#13 terminal/All Detect “C” Common.       

Jumper wire

 from terminal #14/All Detect “NO” Normally Open to #17 terminal/GND.

Red wire

 from inside the gray DA-REPEATER cable to #13 terminal/All Detect “C” Common.        

Black wire from inside the gray DA-REPEATER cable to #14 terminal/All Detect “NO” Normally Open.

Red wire

 from DA-655 to #1 te24DC.        Black wire from DA-655 to #2 terminal/GND.        

Green wire

 from DA655 to #14 

terminal/All Detect “NO” Normally Open.       

Jumper wire

 from terminal #1/+24DC to #13 terminal/All Detect “C” Common.

10

DA-700 Control Panel Hooking Up Other Equipment

Black

Red

Green

Jumper

Black

Red

Black

Red

Green

Jumper

Содержание Drive-Alert DA-700

Страница 1: ...tes alarm panels or other equipment 7 Add a repeater to send the signal another 1000 feet to trigger alerts in other buildings or add a DA 660 booster antenna for buildings up to 3 4 mile away 8 Monit...

Страница 2: ...ns page Use of an unlimited Wireless Sensor Transmitters DA 610TO DA 611TO DA 612TO with a DA 700 Control Panel Receiver Compatible with Mier Accessories detailed in this manual See Accessories Page a...

Страница 3: ...the first Transmitter on Zone 2 Pin for Zone 2 in the second and Zone 3 Pin for Zone 3 in the third The Control Panel will now respond with a different chime for each Zone Test by turning on one Sens...

Страница 4: ...directions Lightning strikes cause a large disturbance in the magnetic field so nearby strikes will cause an alarm It is also possible for electrical current variations in nearby power lines to cause...

Страница 5: ...the underside of the cover Failing to do these things will result in moisture entering the enclosure The Sensor Transmitter can now be placed in position For maximum range the black box Transmitter p...

Страница 6: ...mpers on the Zone Pins on the electrical board in the black box to active them AND pull the jumper off of the JP3 Jumper Pin inside the white DA 700 or DA 100 Control Panel The Drive Alert will give a...

Страница 7: ...he next page for instructions on setting the time and activating the Mute Delay as well as setting the Relay Timer for accessories The RL5 D12 LED red is on when the Control Panel Receiver detects a v...

Страница 8: ...ops flashing if you have depressed the Green Button 1 2 3 or 4 times your program is set Move the SW3 switch back to the Mute position to keep both the Timer and the Mute in ready mode so they can be...

Страница 9: ...ternal Mute Delay button is not convenient 16 Mute Delay Accessory Switch Input for Mute Delay Control if green internal Mute Delay button is not convenient 17 Gnd Ground or 24VDC or 12VDC 18 12DC 12V...

Страница 10: ...nel DA 066MP Wireless Chime Transmitter up to 100 ft 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 24 Gnd Z 1 Z 2 Z 3 Timer Relay All Det Relay Mute P B Gnd 12 Not 10 0 DC or Relay Relay Relay 4...

Страница 11: ...24 C NO C NO C NO NC C NO NC C NO 12 Batt Two Gray wires from the DA 606LK wireless light transmitter one goes to 13 terminal All Detect C Common and the other goes to terminal 14 All Detect NO Normal...

Страница 12: ...is used to hide the DA 610 Sensor HARD WIRED DRIVE ALERT ACCESSORIES DA 655 DA 500LKA DA 052V DA 505 DA 505W DA 050 The Hard Wired DA 655 Chime with Volume Control is our most popular accessory for t...

Страница 13: ...es a signal from up to 1000 feet of any of Mier s wireless Sensor Transmitters OR a DA REPEATER shown above and provides a pleasant tone as an alert It also includes volume control The DA 611TO and DA...

Страница 14: ...Microamp 12 Active Current 3 Milliamp 13 Battery Life One Year in residential installation but up to 5 years if using lithium batteries 14 Operating Temperature 40 DEGREES F TO 125 DEGREES F 15 Weight...

Страница 15: ...und this is above the non ferrous belt line Mount the Sensor securely IT MUST BE STABLE AND MOTIONLESS Any movement of the sensor will cause an alarm Don t mount the Sensor on a tree post or gate that...

Страница 16: ...20 apart OK Check that All Detect red LED RL5 D12 on in the Control Panel when a detection and transmission was to occur Note listen for a Relay click OK If using a long range reception antenna check...

Страница 17: ...rive Alert accessories and parts built by other OEMs including but not limited to chimes lamp modules light switches bells splice kits are covered under their respective OEM warranties This warranty c...