Technical Information
58
T 980x/T 982x
Cause:
Heater bank is not heating.
Remedy:
Check the heater element (R1) for a short or open circuit.
Cause:
Heater relay (K1/1).
Remedy:
Check the heater relay (K1/1).
Cause:
Temperature limiter (SOD, F2).
Remedy:
Check the temperature limiter (SOD, F2) for an open circuit.
Cause:
Defective residual moisture sensor (B3/1).
Remedy:
Residual moisture sensor (B3/1): Check the sampler.
Check the residual moisture sensor (B3/1) voltage circuit for high ohmic (isolation)
status; see Section 090-4.3.
3.14
F66: Air Leakage
Symptom:
Program stop, cooling phase, intermittent buzzer tone for 2 minutes.
Cause:
Air paths clogged.
Insufficient air measurement; refer to Section 090-2.7.
Remedy:
Clean the air paths.
3.15
F98: No Gas Ignition (T 982x only)
Symptom:
Program stop, cooling phase, intermittent buzzer tone.
Cause:
The burner has not ignited after 10 attempts.
Remedy:
Check the following:
- Gas supply is open
- Gasline pressure is available
- Exhaust passageway is clear
- Gas jet is clear
- Ignition electrode is functioning
Note:
In order to clear this fault message, open and close the door with the
appliance switched on.
Содержание T 980x
Страница 1: ...TECHNICAL INFORMATION T 980x and T 982x Dryers US Models 2010 Miele USA ...
Страница 12: ...Technical Information 12 T 980x T 982x 010 Casing Front Panel ...
Страница 16: ...Technical Information 16 T 980x T 982x 020 Door Lock ...
Страница 20: ...Technical Information 20 T 980x T 982x 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 28: ...Technical Information 28 T 980x T 982x 031 Gas Heating T 982x ...
Страница 40: ...Technical Information 40 T 980x T 982x 040 Motor Fan ...
Страница 44: ...Technical Information 44 T 980x T 982x 050 Air Shield Front Bearing ...
Страница 49: ...Technical Information 49 T 980x T 982x 090 Fascia Panel Electronic ...
Страница 66: ...Technical Information 66 T 980x T 982x 100 Electrical System ...