Technical Information
29
T 980x/T 982x
1 Technical
Data
Heating mode
Gas; for electric, refer to Table 030-2.
Gas burner
Gas burner, pipe configuration, 5.7kW. Model: Venturi
Natural-gas version -
output
5.4kW ANSI Gas A, 1076 BTU/ft
3
Temperature sensor
Heater bank NTC (2R30)
Temperature limiter
Two 3/4” bi-metal temperature limiters (1F1, 2F1) with
manual reset, 16A, 248°F/212°F ± 5 K
Safety time; refer to
Section 031-2.1.3
≤
90 seconds
Table 031-1:
Gas Heating Data
2 Function
2.1 Gas
Unit
2.1.1
Gas Solenoid Valve (Y57)
In gas dryers, gas solenoid valve Y57 is activated via heater relays 1K1/1
and 2K1/1.
Gas solenoid valve Y57 consists of gas solenoid valves Y57/1 and Y57/2.
Gas solenoid valve Y57/1, in turn, consists of a maintaining coil and a
booster coil.
Gas solenoid valve Y57 only opens when both solenoid valves (Y57/1
and Y57/2) are opened.
Gas solenoid valve Y57/1 only opens when its maintaining and booster
coils carry voltage.
Once gas solenoid valve Y57/1 is open, it remains in this state as long as
its maintaining coil carries voltage.
Содержание T 980x
Страница 1: ...TECHNICAL INFORMATION T 980x and T 982x Dryers US Models 2010 Miele USA ...
Страница 12: ...Technical Information 12 T 980x T 982x 010 Casing Front Panel ...
Страница 16: ...Technical Information 16 T 980x T 982x 020 Door Lock ...
Страница 20: ...Technical Information 20 T 980x T 982x 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 28: ...Technical Information 28 T 980x T 982x 031 Gas Heating T 982x ...
Страница 40: ...Technical Information 40 T 980x T 982x 040 Motor Fan ...
Страница 44: ...Technical Information 44 T 980x T 982x 050 Air Shield Front Bearing ...
Страница 49: ...Technical Information 49 T 980x T 982x 090 Fascia Panel Electronic ...
Страница 66: ...Technical Information 66 T 980x T 982x 100 Electrical System ...