Technical Information
45
T 980x/T 982x
1 Technical
Data
Filter
Flat filter
Drying air temperature sensor
NTC (1R30)
Table 050-1:
Air Shield Data
3
Fault Repair
3.1 Vibration
Noises
from the Base Plate
Cause:
The exhaust module vibrates during appliance operation, which causes
vibrations in the base plate of the appliance. A buzzing or humming noise is
generated.
Remedy:
Insert a sealing strip (mat. no. 06808080) between the exhaust module
and the base plate:
1. Disconnect the machine from the power supply.
2. Remove the front panel; see Section 010-4.2
3. Place a thin flathead screwdriver between the exhaust module and the
base plate.
4. Use a thicker screwdriver to widen the gap between the exhaust module
and the base plate.
5. Remove the protective film from the sealing strip.
6. Insert the sealing strip into the gap and adhere it under the groove under
the exhaust module, making sure that the strip is centered.
7. Remove the thin screwdriver.
8. Replace the front panel.
Figure 050-1:
Sealing Strip Installation
Содержание T 980x
Страница 1: ...TECHNICAL INFORMATION T 980x and T 982x Dryers US Models 2010 Miele USA ...
Страница 12: ...Technical Information 12 T 980x T 982x 010 Casing Front Panel ...
Страница 16: ...Technical Information 16 T 980x T 982x 020 Door Lock ...
Страница 20: ...Technical Information 20 T 980x T 982x 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 28: ...Technical Information 28 T 980x T 982x 031 Gas Heating T 982x ...
Страница 40: ...Technical Information 40 T 980x T 982x 040 Motor Fan ...
Страница 44: ...Technical Information 44 T 980x T 982x 050 Air Shield Front Bearing ...
Страница 49: ...Technical Information 49 T 980x T 982x 090 Fascia Panel Electronic ...
Страница 66: ...Technical Information 66 T 980x T 982x 100 Electrical System ...