Technical Information
52
T 980x/T 982x
2.6
Overriding the Time Control
A fixed maximum time of approximately 180 minutes is imposed on all
residual moisture drying programs at program start. After this time has
elapsed, any drying program is stopped and the cooldown phase for faults is
carried out. There is no anti-crease action, and no fault code is indicated, but
the fault is saved and can be called up in service mode.
2.7
Insufficient Air Detection
The heater bank NTC (2R30) monitors the temperature increase in the heater
bank. If the air paths are clogged during heating, the temperature in the
heater bank rises rapidly. This is detected and the fault message
Insufficient
air
is displayed. If the temperature at the heater bank NTC exceeds 356°F
(180°C), fault code F66 (
Leaking air
) is issued.
2.8 Operating
Hours
Counter
The time is counted from program start to the end of cooldown, without the
time for delay start and anti-crease action.
2.9 Low-Voltage
Detection
The motor can only run with sufficient supply voltage. Because the motor is
mechanically linked to the fan, no air current is created when the motor is not
running. The dryer will then overheat during heating and trip the circuit
breaker.
In order to avoid overheating, shut the dryer electronics off completely when
they detect low voltage. This is the case when the supply voltage:
- falls below the emergency threshold
- falls below the lower low-voltage value for longer than one second
- falls below the lower low-voltage value more than once in 10 seconds
When the upper low-voltage value (see Table 090-3) has been reached, the
dryer electronics may be switched back on.
Emergency
Threshold
Lower Low
Voltage
Upper Low
Voltage
Forced appliance
shutoff
Secure appliance
shutoff
Secure appliance
switch-on
Tolerance: ± 1.5%
of the nominal
voltage
Tolerance: ± 1.5%
of the nominal
voltage
Tolerance: ± 1.5%
of the nominal
voltage
USA (120V, 60Hz)
< 80V
< 102V - 3% of the
nominal voltage
> 108V - 3% of the
nominal voltage
Table 090-3:
Values for Low-Voltage Detection
Содержание T 980x
Страница 1: ...TECHNICAL INFORMATION T 980x and T 982x Dryers US Models 2010 Miele USA ...
Страница 12: ...Technical Information 12 T 980x T 982x 010 Casing Front Panel ...
Страница 16: ...Technical Information 16 T 980x T 982x 020 Door Lock ...
Страница 20: ...Technical Information 20 T 980x T 982x 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 28: ...Technical Information 28 T 980x T 982x 031 Gas Heating T 982x ...
Страница 40: ...Technical Information 40 T 980x T 982x 040 Motor Fan ...
Страница 44: ...Technical Information 44 T 980x T 982x 050 Air Shield Front Bearing ...
Страница 49: ...Technical Information 49 T 980x T 982x 090 Fascia Panel Electronic ...
Страница 66: ...Technical Information 66 T 980x T 982x 100 Electrical System ...