Technical Information
55
T 80xx
3.15
F66 - Air Leakage
Symptom:
This fault occurs in the normal operating mode.
“Filter/Vent” LED lights up.
Program stop.
Cooldown.
Buzzer intermittently for 2 minutes.
Cause:
Air paths are clogged.
Insufficient-air detection; refer to Section 090-2.7.
Remedy:
1.
Vented and condenser dryers:
Clean the air paths.
2. Clean and dry the door lint filter.
3.
Vented dryers only:
Clean the vent grille.
4.
Condenser dryers only:
Clean and dry the fill-ring lint filter.
5.
Condenser dryers only:
Clean the heat exchanger.
Note:
To delete this fault indication, disconnect the dryer from power.
3.16
Laundry is Overdried/F55 (Overriding Time Limit Exceeded)
Symptom:
Very long operating time.
F55 is stored in the fault memory.
Cause:
Short circuit at drum contact strip. A metal bracket of the drum contact strip is
touching the drum casing and has caused a short circuit. Therefore, the
electronics are detecting moisture, even though the laundry is already dry.
Remedy:
1. Insulate the bracket from the drum casing:
2. Place an insulating sleeve (mat. no. 07244210) around the bracket.
Note:
In order to clear this fault message, open and close the door with the
appliance switched on.
3.17
Appliance Not Functioning/Wrong Version Detected
Symptom:
Although the appliance is a condenser dryer, a vented dryer is recognized.
“Vented” is displayed in the MDU.
In service mode the buzzer buzzes continuously for the “vented” version.
Cause:
Moisture in the area of the condensate pump. Moisture in the reed switch (on
or in the plug) will cause contact resistance, so that the condensate pump is
Содержание T 80 Series
Страница 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Страница 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Страница 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Страница 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Страница 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Страница 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...