Technical Information
46
T 80xx
2.1.4 Memory
With this function activated at program start, the program and all extra
functions selected are saved.
When the dryer is next switched on, the most recently selected program will
be preset.
Delay start
is not saved
.
2.1.5 Additional
Cooldown
Phase
Hot laundry is perceived as damp.
To reduce the perception of “damp laundry”, an additional cooling phase can
be set, resulting in a lower laundry temperature at the end of the program. To
the operator, the laundry then feels less damp.
The extended cooling phase has no effect on timed drying programs.
2.1.6
Prompt to Clean Air Ducts (“Filter/Vent” Display Adjustment)
The operator can set the “Filter/Vent” LED to suit individual requirements.
For insufficient air detection, refer to Section 090-2.7.
2.1.7
Acoustical Acknowledgment for Touchpads
Set the acoustical tone to sound when a button is pressed.
2.2 Service
Functions
2.2.1 Software
Status
The control/power electronic (1N1, EPWL) has programmable electronic
assemblies which contain the software/programs and parameters for the
drying-process technology.
The status of the software can be seen from the
ID number or program
index
.
The software can be updated via the optical interface.
Note:
In models with display
, the software status is indicated via the
ID number
.
In models without display
, the software status is indicated in the
program
index
via the flashing rhythm of the LED.
2.2.2 Fault
Memory
The control/power electronic (1N1, EPWL) monitors electrical sensors.
If the electronic registers a fault, then
the program is stopped, if necessary,
the fault is indicated via the “Drying” LED,
in case of a technical fault, a fault code is saved.
Содержание T 80 Series
Страница 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Страница 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Страница 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Страница 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Страница 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Страница 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...