Technical Information
25
T 80xx
1. Check the front bearing seals (front and back needle felting) for correct
position.
2. Check that the bearing bushing of the drum is firmly snapped in.
3. Check the bearing of the front support roller; adjust as necessary.
Cause:
The intermediate V-belt power transmission is faulty.
Remedy:
Check the intermediate V-belt for dirt deposits, wear and tear, and insufficient
spring tension.
Cause:
The power transmission from the V-belt to the drum is faulty.
Remedy:
Check the drum V-belt for soiling, wear and tear, and insufficient spring
tension.
4 Service
4.1
Heater Bank Removal
1. Disconnect the appliance from the power supply.
2. Remove the dryer lid; refer to Section 010-4.1.
3. Remove the T20 screws (up to 12) securing the metal rear service panel.
Take off the metal rear service panel.
4. Release the heater bank NTC from the heater bank housing.
5. Release the wiring harness from the holder (Figure 030-1, Item 1).