Technical Information
42
T 80xx
1 Technical
Data
Condensate pump (M5)
Approximate power rating 25W
Pressure hose length 4.9'
(1.5m)
Maximum head height
4.9' (1.5m)
Maximum head height with non-return valve
3.3' (1m)
Maximum drain length
13' (4m)
Control
Time- and level-controlled
Table 070-1:
Technical Data
4 Service
4.1
Rear Service Panel Removal
1. Remove the T30 screw securing the plastic rear service panel (Figure
070-1, Item 1).
2. Take off the rear service panel; remove the hose from the panel.
Figure 070-1:
Rear Service Panel
4.2
Condensate Pump Removal
Note:
Have cloths or rags handy!
1. Disconnect the appliance from the power supply.
2. Remove the rear service panel; see Section 070-4.1.
3. Take off the metal clamp.
4. Lift the pump up and out of the condensate box.
Содержание T 80 Series
Страница 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Страница 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Страница 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Страница 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Страница 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Страница 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...