50
T 80xx
Cause:
The condensate pump (M13) is defective.
Remedy:
Check the condensate pump in the component test; refer to Section 090-4.3.
Cause:
Short circuit in the condensate float switch (B8/7).
Remedy:
Check the condensate float switch (B8/7):
Check the reed contact at the
condensate float switch for a short circuit. Check both the float and the
magnet.
Note:
To delete this fault indication, open and close the door with the dryer
switched on.
3.4
“Filter/Vent” LED Lights Up
Symptom:
Normal program cycle.
Fault display at the end of the cooling air phase.
Insufficient-air detection; refer to Section 090-2.7.
Cause:
Air paths are clogged.
Remedy:
1.
Vented and condenser dryers:
Clean the air paths.
2. Clean and dry the door lint filter.
3.
Vented dryers only:
Clean the vent grille.
4.
Condenser dryers only:
Clean and dry the fill-ring lint filter.
5.
Condenser dryers only:
Clean the heat exchanger.
Cause:
”Filter/Vent” LED is displayed prematurely.
Remedy:
Modify the “Filter/Vent” LED indication; refer to Section 090-2.1.6 or the
operating instructions.
Note:
To delete this fault indication, open and close the door with the dryer
switched on.
3.5
All LEDs Flash/Demo Mode Active
Symptom:
No program start; access to programming or service mode is not possible.
Cause:
Demo mode is active.
Remedy:
To deactivate the demo mode, refer to Section 090-4.2.
Содержание T 80 Series
Страница 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Страница 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Страница 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Страница 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Страница 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Страница 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...