Technical Information
32
T 80xx
2 Function
2.1 Preferred
Orientation/Counter Orientation
Preferred orientation: The radial fan is optimized for airflow in this direction.
Counter orientation: Opposite to the preferred orientation.
Note:
To prevent overheating, the heater output is limited when the fan is in
counter orientation.
4 Service
4.1
Drum Rib Removal
1. Remove the lid; see Section 010-4.1.
2. Manually turn the drum until the four screws (Figure 040-4, Items 1 and 2)
securing the drum rib are visible.
3. Remove the four screws (Figure 040-4, Item 1).
4. Remove the connection screw (Figure 040-4, Item 2) for the contact strip
(Figure 040-4, Item 3).
Figure 040-4:
Drum Rib
4.2
Contact Strip Removal
1. Remove the lid; see Section 010-4.1.
2. Remove the screws securing the contact strip.
3. Spin the drum 180° and remove the screws from the second drum rib.
4. Pull the contact strip off of the drum.
4.3
Fan Impeller Replacement
1. Disconnect the machine from the power supply.
2. Remove the dryer lid; see Section 010-4.1.
3. Remove the fascia panel; see Section 090-4.4.
Содержание T 80 Series
Страница 1: ...TECHNICAL INFORMATION T 80xx Dryers US Models 2019 Miele USA ...
Страница 17: ...Technical Information 17 T 80xx Figure 010 2 Metal Support Bracket ...
Страница 21: ...Technical Information 21 T 80xx 030 Drum Rear Bearing Residual Moisture Sensor Heater Bank ...
Страница 36: ...Technical Information 36 T 80xx 050 Fill Ring Air Shield Front Bearing ...
Страница 39: ...Technical Information 39 T 80xx 060 Condensate Box ...
Страница 41: ...Technical Information 41 T 80xx 070 Condensate Pump ...
Страница 44: ...Technical Information 44 T 80xx 090 Fascia Panel Electronic ...