Installation of the ducting
*
I
N
S
T
A
L
L
A
T
I
O
N
*
68
Sample calculation
A
Wall pipe, with inserted grate
= 1 x 3.8 m relative pipe length
= 3.8 m
B/D 2 bends, 90° plastic waste
water pipe
= 2 x 0.8 m relative pipe length
= 1.6 m
C
0.5 m plastic waste water pipe
= 0.5 x 1 m relative pipe length
= 0.5 m
Total ducting length
= 5.9 m
Because the total ducting length is less
than 20 m (according to table II), a pipe
diameter of 100 mm will be sufficient.
Exhaust air outlets on the back
of the tumble dryer
Sealing the air outlets
The ducting is installed on the right or
left side of the tumble dryer's back
panel. You must seal the unused
connection with a cap.
Turn the cap to the left to remove it.
Press the cap firmly into the open air
outlet.
Dimensions of the exhaust air outlets
100
92
100
100
92
All measurements in mm
Содержание PDR 908 EL
Страница 96: ...M Nr 11 226 810 02 en AU NZ PDR 908 EL ...