Frequently Asked Questions
78
Problem
Possible cause and solution
The compressor is turn-
ing on more frequently
and for longer periods
of time; the temperature
inside the Wine Storage
Unit is too low.
The ventilation gaps in the cabinetry have been cov-
ered or become too dusty.
Do not block the ventilation grille.
Clean the ventilation grille on a regular basis to re-
move any dust.
The door has been opened too frequently, or a large
number of bottles have been put inside the unit all at
once.
Only open the door when necessary and for as
short a time as possible.
After a while, the temperature will return to normal by
itself.
The appliance door is not properly closed.
Close the door.
After a while, the temperature will return to normal by
itself.
The ambient temperature is too high. The higher the
ambient temperature, the longer the compressor has
to run.
See “Installation location” in “Installation informa-
tion”.
The Wine Storage Unit has not been installed properly
in the niche.
See “Installing the Wine Storage Unit” in “Installa-
tion information”.
The compressor comes
on less and less often
and for shorter periods
of time. The tempera-
ture inside the Wine
Storage Unit rises.
This is not a fault. The temperature setting is too high.
Correct the temperature setting.
Check the temperature again after 24 hours.
The compressor runs
continuously.
Not a fault. To save energy, the compressor runs at a
lower speed when less cooling is required. This in-
creases the compressor run time.
An alarm sounds.
The door of the Wine Storage Unit has been open for
longer than approx. 2 minutes.
Close the door.
Содержание KWT 2601 SF
Страница 10: ...IMPORTANT SAFETY INSTRUCTIONS 10 The surface is easily scratched Even magnets can cause scratch ing ...
Страница 20: ...Dimensions when the appliance door is opened opening angle 90 Installation dimensions 20 ...
Страница 33: ...Installing the wine conditioning unit Click the baseboard onto the bot tom of the appliance base 33 ...
Страница 86: ...Declaration of conformity 86 Frequency band 2 412 GHz 2 462 GHz Maximum trans mitting power 100 mW ...
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 92: ...M Nr 10 785 220 00 en US CA KWT 2601 SF KWT 2611 SF ...