Installation
*INSTALLATION*
89
Hardwired electrical connection
It is possible to hardwire this appliance
to an existing power cable.
CAUTION: Before servicing,
disconnect the power supply by
either removing the fuse, shutting off
the power main or manually
“tripping” the circuit breaker.
Installation work and repairs should
only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and service by unqualified
persons could be dangerous and the
manufacturer cannot be held
responsible.
Before connecting the appliance to
the power supply, make sure that the
voltage and frequency listed on the
data plate correspond with the
household electrical supply. This
data must correspond to prevent
machine damage. Consult an
electrician if in doubt.
GROUNDING INSTRUCTIONS
THIS APPLIANCE MUST BE
GROUNDED.
This appliance must be connected to a
grounded metal, permanent wiring
system, or an equipment-grounding
conductor must be run with the circuit
conductors and connected to the
equipment-grounding terminal or lead
on the appliance.
Prior to making a hardwire
connection to the terminal, remove
the powercord. Otherwise there will
be a risk of electric shock from the
attached plug.
An existing flexible supply cord or cable
shall have a minimum thickness of
AWG 14.
120 V, 60 Hz, 15 A fuse rating
Black wire (live): connect to L
White wire (neutral): connect to N
Green wire (ground): connect to
After attaching the permanent
power supply cord, check that all
wires are correctly and securely
placed in the connector and the
strain relief is tightened.