![Miele professional PW 413 SES Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/miele-professional/pw-413-ses/pw-413-ses_operating-and-installation-instructions_1793182066.webp)
Settings option
66
Dispensing throughput (D1 to D13)
The throughput of the connected dispenser pumps can be set from
0 ml/min to 9999 ml/min in 1 ml/min steps.
Access the following content:
Supervisor level
Settings
Dispensing throughput
Dispensing correction factor
OK
Select "Dispensing throughput".
The following will appear in the display:
Settings
Dispensing throughput
Dispenser pump 1
Dispenser pump 2
OK
: 100,0 ml/min
100,0 ml/min
:
Options:
– No
– 1 to 9999.0 ml/min
Dispensing correction factor (D1 to D13)
The correction factor can be used if an adjustment is made to the
liquid dispensing. If, for example, the dispensing agent for dispenser
pump D1 were altered (to a higher concentration), a quick adjustment
can be made with the correction factor.
Calculate the correction factor using the following formula:
Correction factor D1 =
New quantity Dos-p. D1
Current quantity Dos-p. D1
Access the following content:
Supervisor level
Settings
Dispensing correction factor
Dispenser level reminder
OK
Select "Dispensing correction factor".
Supervisor level
Settings
Dispenser pump 1
1,00
OK
:
Dispenser pump 2 1,00
:
You have the following options:
– 0.01 to 1.99
– 2