Optional modules
33
Commissioning the dispenser pumps
Before the liquid dispenser pumps can be used, the liquid detergent
must be drawn into the system and the amount to be dispensed set.
Dispenser calibration
Dispenser calibration is used to measure the throughput of individual
dispenser pumps.
To go directly to
Dispenser
calibration when
the machine is
switched off:
Press and hold multifunction button 2 and switch the machine on
with
"Power On".
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Options:
–
Dispenser pump
1
to
13
Select
Dispenser pump 1
, for example.
When a dispenser pump is selected, the following will appear in the
display:
Dispenser calibration
Dispenser pump 1
-
OK
+
V:
100 ml
0/1
0 s
t:
P: No
Useful tip:
The dispensing amount can be set from 0 to 9999 ml in
1 ml increments.
Press the multifunction button
0/1
.
The dispensing hose will fill up.
Stop the process by pressing the
0/1
button.
Run the hose of the dispenser pump upwards into a measuring
vessel.
Hold the entire measuring vessel above the dispenser pump while
doing this.
Irritant detergents!
Can cause skin and eye irritation.
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing
"Back".