Settings option
63
Buzzer
If "Yes" is programmed, the buzzer is activated along with the
programme stop signal 1 and 2, the block end signal and the fault
stop signal. The buzzer frequency is increased with the fault stop
signal. The buzzer is switched off after 5 minutes or when a button is
pressed.
If "No" is programmed, the buzzer is switched off.
Options:
– No
– Yes
Maximum temperature selection
This value can be set from cold to 95 °C in 1 °C increments and limits
all temperature settings in the programmes to the selected value. This
means that when 60 °C is selected, for example, the water will not be
heated to more than 60 °C in any programme even if a higher
temperature is programmed for the selected programme.
Options:
– Cold
– 15 to 95 °C
Display standby
If the "Display Standby: yes" setting is selected, the display is
switched on by pressing any button. If no further buttons are
pressed after 10 minutes, the machine returns to "Standby". The
start button light ring flashes to inform you of this. When a button is
pressed, the display is switched on again and the last active screen
appears.
When "Display standby: No" is set, the display is permanently on.
Choose from the following options:
– Yes
– No
Contrast setting
The display contrast can be altered from 1 to 10. This allows the
display to be optimised for specific working conditions. When it is
altered, the contrast is changed immediately.
Options:
– 1 to 10
Clock display
You can select either the 24-hour or 12-hour clock for the display.