4

 

Write fail 

29

Temperature units 

30

Power Supply Voltage 

30

Buzzer 30
Diagnostic Voltage Limit 

30

Diagnostic Amp Limit 

30

Pag Code 

30

Display 30

Contrast Level 

30

Problems with the Display 

30

Language 30
Shop info 

31

Coupon 31
Format Card 

31

Update 31
BMIS Data Send 

31

WiFi Settings 

31

Scan for Network 

31

Manual Entry 

32

Version info 

32

Chapter 12: Errors and warnings 

33

Reverse Connection 

33

Check Clamp connection 

33

Frozen Battery 

33

Battery Temperature above limit 

33

Содержание GRX-3080 JLR EU

Страница 1: ...INSTRUCTION MANUAL GRX 3080 JLR EU Battery Diagnostic Station Standalone version ...

Страница 2: ...This page intentionally left blank ...

Страница 3: ...harge 17 Inspecting the Battery 17 Connecting the Clamps 17 Chapter 5 Diagnostic Charging 18 Charging Modes 19 Initial Analysis 19 Hard to Charge Mode 19 Bulk Charge Mode Fill Mode 19 Extended Charge Mode 19 Top Off Mode 19 Aborting a charge session 19 Completing a charge session 20 State of Health 20 Chapter 6 PDI Storage 21 Charging Modes 22 Initial Analysis 22 Hard to Charge Mode HTC Mode 22 Bu...

Страница 4: ...t 30 Diagnostic Amp Limit 30 Pag Code 30 Display 30 Contrast Level 30 Problems with the Display 30 Language 30 Shop info 31 Coupon 31 Format Card 31 Update 31 BMIS Data Send 31 WiFi Settings 31 Scan for Network 31 Manual Entry 32 Version info 32 Chapter 12 Errors and warnings 33 Reverse Connection 33 Check Clamp connection 33 Frozen Battery 33 Battery Temperature above limit 33 ...

Страница 5: ...result in a risk of electric shock or fire 1 7 To reduce risk of electric shock unplug the charger from the AC outlet before attempting any maintenance or cleaning Turning off the controls will not reduce this risk Remove marine boat batteries and charge them on shore Charging marine batteries on board requires specially designed equipment for marine use 1 8 Connect and disconnect the battery lead...

Страница 6: ...ltage If the charger has an adjustable charge rate charge the bat tery initially at lowest rate If the charger has only one voltage verify that the battery voltage matches the volt age of charger For a charger not having an output voltage selector switch determine the voltage of the battery by referring to car owner s manual and make sure it matches the output rating of the battery charger Groundi...

Страница 7: ...the vehicle to reduce the risk of explosion 7 1 Before working on the vehicle firmly apply the emer gency brake and place the gear shift to NEUTRAL shift an automatic transmission to PARK 7 2 Locate the charger as far away from the battery as the charger cords permit and position the AC and DC cords to avoid stepping on or tripping over them and to pre vent damage by hood doors or moving engine pa...

Страница 8: ...en making the final connection then connect the NEGATIVE BLACK charger clamp to the free end of the cable 8 5 When disconnecting the charger always do so in the re verse sequence of the connecting procedure break the first connection while staying as far away from the bat tery as practical Safety Reminder For safe efficient and accurate charging and testing review the safety and operating instruct...

Страница 9: ...have potentially adverse affects on the environment and your health Conventions used in this manual To help you learn how to use your charger the manual uses these symbols and typographical conventions Convention Description The safety symbol indicates instructions for avoiding hazardous conditions and personal injury The safety symbol with the words CAUTION WARNING or DANGER indicates instruction...

Страница 10: ...ee screws are included to secure the cables To attach the cables 1 Plug the small connector into the small socket A on the back of the unit 2 Plug the large connector B into the large socket while placing the protective cover C against the back of the unit 3 Center the three holes in mounting bracket over the bolts and lower the bracket onto the charger Reinstall the hardware in this order the fla...

Страница 11: ...ate transitions and warnings Expansion plug in module bay Room for 5 expansion modules Available are Amp clamp DMM probes Zigbee WIFI Bluetooth Serial connection extra USB connection Display Backlit graphical display and keypad for data entry Alphanumeric keypad Keypad for data entry and selections in the various menus GRX Battery Diagnostic Station Front View The controls to the GRX Battery Diagn...

Страница 12: ... Hardware prepared functionality to be defined GRX Battery Diagnostic Station Rear View In addition to containing the outlet for the charger cables and power cord the back of the unit is the location for the serial number label and the ON OFF switch Serial Number Label The serial number of the unit ON OFF switch Switch the unit on or off AC Power cord Connection for a grounded nominal 220 VAC outl...

Страница 13: ... bar shows you the name of the current menu test tool utility or function Selection Area The selection area below the Title Bar contains selectable icons or dialog boxes that display information or require a response Menu Screen Arrows When displayed in menu screens the menu screen arrows show you which ARROW key on the keypad to press to display other icons or screens The Up and Down Menu Screen ...

Страница 14: ...RROW key to move the dot to the button next to the item To confirm your selection press the appropriate soft key You can also use the alphanumeric keypad to enter the number preceding the option button of your choice No additional key press is needed to proceed Scrolling Lists A scrolling list contain items that extend above and below the screen The first number above the right soft key indi cates...

Страница 15: ...nu includes functionality to setup the charger Menu icons marked with an asterisk have more functions behind it Utility Menu This menu allows you to set certain preferences and view options Menu Icon Description The CONFIG CHARGER menu allows you to set the following parameters DATE AND TIME WRITE FAIL TEMPERATURE UNITS POWER SUPPLY VOLTAGE BUZZER DIAGNOSE VOLT LIMIT and DIAGNOSE AMP LIMIT The DIS...

Страница 16: ...1 DD MM YYYY Day Month Year 2 MM DD YYYY Month Day Year 2 Press the NEXT soft key to save your setting or the BACK soft key to return without saving the changes Date 1 Use the ARROW keys to highlight the month day or year 1 1 2015 2 Press the NEXT soft key to save your setting or the BACK soft key to return to the previous page without saving the changes Time Format Use the UP or DOWN ARROW key or...

Страница 17: ...lled water to the level indicated by the battery manufacturer Do not overfill Corroded or loose battery terminals tray and hold down fixture Tighten or replace as needed Connecting the Clamps Connect the charging clamps to the battery in accordance with all precautions and safety instructions Do not connect either clamp to the vehicle s chassis Connect the clamps to the battery posts negative blac...

Страница 18: ...RROW key to select the BATTERY TYPE or press the corresponding numeri cal keys to move the dot to the option button of your choice 1 AGM 2 REGULAR FLOODED Press the NEXT soft key to continue 6 Use the UP or DOWN ARROW key to select the RATING UNIT TEST STANDARD or press the corre sponding numerical keys to move the dot to the option button of your choice 1 EN 2 CCA SAE 3 DIN 4 JIS If you select JI...

Страница 19: ...charge acceptance and condition during the charge Before and during the charge cycle the battery is tested with both Conductance and a Load bounce Hard to Charge Mode HTC Mode The GRX uses the first portion of the total charge cycle to closely monitor the acceptance of charge current and energy going in to the battery During this mode the charger continuously analyzes the battery to make a decisio...

Страница 20: ...al changes until eventually the battery can no longer hold a charge and supply the power necessary to start the car and provide auxiliary power to the electrical system As the battery approaches end of life its deterioration accelerates until it finally fails to start the vehicle Before failing the battery may start the vehicle under normal conditions but may not be able to operate in more extreme...

Страница 21: ... key to select the BATTERY TYPE or press the corresponding numeri cal keys to move the dot to the option button of your choice 1 AGM 2 REGULAR FLOODED Press the NEXT soft key to continue 7 Use the UP or DOWN ARROW key to select the RATING UNIT TEST STANDARD or press the corre sponding numerical keys to move the dot to the option button of your choice 1 EN 2 CCA SAE 3 DIN 4 JIS If you select JIS th...

Страница 22: ...ring the charge Before and during the charge cycle the battery is tested with both Conductance and a Load bounce Hard to Charge Mode HTC Mode The GRX uses the first portion of the total charge cycle to closely monitor the acceptance of charge current and energy going in to the battery During this mode the charger continuously analyzes the battery to make a decision as quickly as possible Bulk Char...

Страница 23: ...hanges until eventually the battery can no longer hold a charge and supply the power necessary to start the car and provide auxiliary power to the electrical system As the battery approaches end of life its deterioration accelerates until it finally fails to start the vehicle Before failing the battery may start the vehicle under normal conditions but may not be able to operate in more extreme con...

Страница 24: ...0 to 1700 Ah Amp Hour A measure of reserve capacity This is not a battery standard 1 to 300 Ah 5 Press the UP or DOWN ARROW key or use the numeric keys to enter the BATTERY RATING in CCA 500 A EN Press the NEXT soft key to continue 6 Press the UP or DOWN ARROW key or use the numeric keys to enter the BATTERY RATING in Ah AH Press NEXT after entering the rating The GRX Battery Diagnostic Station wi...

Страница 25: ... session press the STOP key until the charge session is aborted After aborting the charge data is displayed Press EXIT to return to the MAIN Menu Completing a Charge Session The charge session is complete when the proper amount of charge is put back into the battery or the remaining estimated time to charge counts down to zero IMPORTANT When you start a new test the last bat tery test in memory wi...

Страница 26: ...this process you use the power supply function Always make sure that when you work on the vehicle the charger is switched in to the Power Supply function so that you ensure that when the work is done the battery s state of charge is maintained at a healthy level From the MAIN Menu highlight the POWER SUPPLY icon and press the SELECT key The GRX 3080 JLR will immedi ately begin to supply power Sett...

Страница 27: ... number with the alphanumeric keypad Press the NEXT soft key to continue Battery Standards Rating System Description Range EN Europa Norm 100 to 1700 DIN Deutsche Industrie Norm 100 to 1000 JIS Japanese Industrial Standard embossed on the battery as a combination of numbers and letters 74 numbers from 26A17 to 245H52 SAE Cold Cranking Amps specified by SAE The amount of current a battery can provi...

Страница 28: ... MENU Clear counters This allows you to reset the counters completely STATISTICS Press the YES soft key to clear the counters or the NO soft key to cancel Problems with the Internal Printer The internal printer will not print Make sure the Battery Diagnostic Station is connected to AC power and the POWER switch is pressed to the ON position Verify that the paper is properly installed Changing the ...

Страница 29: ... numerical key 1 or 2 to move the dot to the option button of your choice 1 MM DD YYYY month day year 2 DD MM YYYY day month year 2 If you used the ARROW keys press the SAVE soft key to save your setting or the BACK soft key to return to the menu If you use the alphanumeric keypad to enter the number preceding the option button no additional keypress is needed to save your selection Date 1 Use the...

Страница 30: ...ft key to save your setting or the BACK soft key to return to the menu screen without saving the changes Diagnostic Amp Limit 1 Use the UP or DOWN ARROW to select the re quired DIAGNOSTIC CURRENT LIMIT 25 A 2 Press the SAVE soft key to save your setting or the BACK soft key to return to the menu screen without saving the changes Pag Code 1 Enter the PAG code 2 Press the SAVE soft key to save your ...

Страница 31: ...ou before formatting the disk and ask you if you want to continue When a new blank data card is used you always have to use this function before the tester can write to the card Update As software updates become available you will be able to use this utility to update the charger software using files on an SD card or you can download the update with the GRX 3080 The use of a special formatted SD c...

Страница 32: ...d press NEXT to continue Press STOP to exit the character map and return to the Utility menu 4 Use or to select the SECURITY TYPE of the network you want to use and press SELECT 1 OPEN 2 WEP 3 WPA 4 WPA2 5 In case of WEP use or to select the WEP TYPE of the network you want to use and press SELECT 1 64 BIT 2 128 BIT 6 Select the KEY slot for theWEP network that you want to use and press SELECT 1 K...

Страница 33: ...both sides of the clamps are gripping the terminals rock the each clamp back and forth A poor connection will prevent charging If the message reappears after you have correctly reconnected the clamps clean the terminals and battery posts and reconnect Frozen Battery A warning from the charger that the battery under charge shows signs of being frozen Thaw the battery and try to charge it later Char...

Страница 34: ...ssembly SERVICE To obtain service contact Midtronics at 866 592 8052 Have your model and serial numbers ready This first step is critical as we will trouble shoot the problem s over the phone and many problems are resolved during this step If the problem cannot be resolved then the Customer Service Agent will issue you a Return Material Authorization RMA This number becomes your tracking number Th...