background image

GR8-1200 OEM

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

21

Inspecting the Battery

Before starting the test visually inspect the battery for:

• 

Cracked, buckled, or leaking case. If you see any of these 
defects, replace the battery.

• 

Corroded, loose, or damaged cables and connections. Re-
pair or replace them as needed.

• 

Corrosion on the battery terminals, and dirt or acid on the 
case top. Clean the case and terminals using a wire brush 
and a mixture of water and baking soda.

• 

Low electrolyte level. If the electrolyte level is too low, add 
distilled water to fi ll up to 1/2 above the top of the plates 
and fully charge the battery. Do not overfi ll.

• 

Corroded or loose battery tray and hold-down fi xture. 
Tighten or replace as needed.

Testing Out-of-Vehicle (Battery Test)

The preferred battery test location is in the vehicle. However, if 
you plan to test out of the vehicle:

• 

Always disconnect the negative cable from the battery 
fi rst and reconnect it last. 

• 

Always use a carry tool or strap to lift and transport the 
battery.

 

CAUTION

When testing side-post or Group 31 

batteries, always use lead terminal adapters pro-
vided with the GR8—do not test at the battery’s 
steel bolts. To avoid damage, never use a wrench 
to tighten the adapters more than 1/4 turn. Fail-
ure to properly install lead terminal adapters, or 
using adapters that are dirty or worn, may cause 
false test results.

Testing In-Vehicle (System Test)

Before starting the test, inspect the alternator drive belt. A belt 
that is glazed or worn, or lacks the proper tension, will prevent 
the engine from achieving the rpm levels needed for the test.

The preferred test position is at the battery posts. If you must 
test at a remote-post location, it should have both a positive 
and negative post. Otherwise, you must remove the battery 
and perform a System Test.

At the start of the test, place the vehicle transmission in PARK, 
make sure all vehicle accessory loads are off , the key is not in 
the ignition, and the doors are closed.

Connecting to the Battery

Connect the charging clamps to the battery in accordance 
with all precautions and safety instructions.  

D

o not connect 

either clamp to the vehicle’s chassis.

Connect the red clamp to the positive (+) terminal and the 
black clamp to the negative (–) terminal. 

If you connect the clamps in the wrong polarity (red to 
negative or black to positive), the analyzer sounds an alarm 
and displays CLAMPS REVERSED! Reconnect the clamps.

To make sure both sides of the clamps are gripping 
the terminals, rock the each clamp back and forth. 
A poor connection will prevent testing, and the analyzer 
displays the message CHECK CONNECTION. If the message 
reappears after you have correctly reconnected the clamps, 
clean the terminals and reconnect.

Connecting to AC Power

Plug the charger into a dedicated, grounded nominal 15-amp 
or higher AC outlet. Press the power switch to the 

ON

 position.

Chapter 4: Test Preparation

Chapter 4: Test Preparation

Содержание GR8-1200 OEM

Страница 1: ...INSTRUCTION MANUAL GR8 1200 OEM INNOVATION TECHNOLOGY QUALITY WORLDWIDE January 2009 167 000101A Multitasking Battery and Electrical Diagnostic Station...

Страница 2: ...GR8 1200 OEM Midtronics Inc 7000 Monroe Street Willowbrook IL 60527 www midtronics com 2 This page intentionally left blank...

Страница 3: ...ging In for the First Time 19 Bootup 19 Selecting A Language 19 User ID 19 Adding a User 19 Multitasking 20 Wireless Multitasking 20 Procedure Summary 20 Setting User Preferences 20 Help Menu 20 Chapt...

Страница 4: ...cuit Test Results 42 Chapter 14 Digital Multimeter DMM 43 DMM 43 DC Volts 43 AC Volts 43 Scope 43 DC AMP requires the optional amp clamp 43 AC AMP requires the optional amp clamp 44 Temp 44 Ohm Meter...

Страница 5: ...e 1 7 To reduce risk of electric shock unplug the charger from the AC outlet before attempting any maintenance or cleaning Turning off the controls will not reduce this risk Remove marine boat batteri...

Страница 6: ...it matches the output rating of the battery charger 4 Grounding Power Cord Connections 4 1 The charger must be grounded to reduce risk of electric shock The charger is equipped with an electric cord h...

Страница 7: ...educe the risk of explosion 7 1 Before working on the vehicle firmly apply the emergen cy brake and place the gear shift to NEUTRAL shift an automatic transmission to PARK 7 2 Locate the charger as fa...

Страница 8: ...explosion Follow these steps when the battery is installed in the vehicle to reduce the risk of explosion WARNING Make sure all vehicle loads are OFF to prevent a possible arc 8 1 Check the polarity o...

Страница 9: ...Never smoke or allow a spark or flame in the vicinity of a battery WARNING REQUIRED BY CALIFORNIA PROP 65 Bat tery posts terminals and related accessories contain lead and lead compounds chemicals kno...

Страница 10: ...ymbols and typographical conventions Table 2 Symbols And Typographical Conventions Assembling the GR8 The GR8 is shipped with the control module and mounting bracket packed separately For easy assembl...

Страница 11: ...e module down at an angle until the bolts are inserted securely into the slots extending from the module s holes Installing the Multitasker Module The GR8 1200 comes with a bracket to hold the multita...

Страница 12: ...l module Backlit graphical display and keypad for data entry oMultitasker module Dual connectors for testing more than one battery simultaneously pON OFF switch Turns power on and off to the GR8 qSTAT...

Страница 13: ...ation for the serial numbers for the charger engine and the control module Both numbers are necessary for warranty registration nSerial number label for control module oSystem test cable connector pCa...

Страница 14: ...m as part of the keys pARROW keys Press the ARROW keys to scroll to numerical values and move to menus and icons qPOWER Key Press the POWER key to turn the control module ON and OFF rTitle Bar The tit...

Страница 15: ...r fashion the soft key below the left half of the screen cancels your choice or returns you to the previous screen although the word above it may also vary Examples BACK and CLEAR Menu Icons A menu ic...

Страница 16: ...represent while others are menu icons that lead to two or more options Table 4 Main Menu Icons Menu Icon Description Automatically tests charges and provides battery decision using the information you...

Страница 17: ...splays wireless communication quality and channel being used Lists the software version version date and serial number DMM Menu The DMM menu has icons for a temperature sensor and 9 test meters some o...

Страница 18: ...the Edit Coupon utility use Coupon to turn it on and off Enables you to create a coupon at the bottom of printed test results Allows you to select degrees in C or F for temperature measurements Sets t...

Страница 19: ...begin testing NOTE The BACK option is only available when the charger is used for the first time Adding a User 1 Use the DOWN ARROW key to scroll to ADD USER Press the NEXT soft key to continue 0 UNR...

Страница 20: ...ed and removed to test another vehicle in the service bay thus acting as two tools in one The Multitasker will control the charge session when the control module is removed The charge session can be m...

Страница 21: ...cause false test results Testing In Vehicle System Test Before starting the test inspect the alternator drive belt A belt that is glazed or worn or lacks the proper tension will prevent the engine fro...

Страница 22: ...move the dot to the option button of your choice 1 IN VEHICLE 2 OUT OF VEHICLE 3 Use the UP or DOWN ARROW key to make your selections or press the corresponding numerical key 1 or 2 1 BELOW 250 MILES...

Страница 23: ...es a decision GOOD BATTERY REPLACE BATTERY or REPLACE BAD CELL For diagnostic charge analysis progress is shown by the left to right movement of a progress bar Deep Scan Test In some cases the GR8 may...

Страница 24: ...nd hold the STOP key until the charging session is aborted After aborting select NEXT to return to the Main Menu Completing a Charge Session The charge session is complete when the proper amount of ch...

Страница 25: ...REPLACE BATTERY result may also mean a poor connection between the battery and the vehicle If you tested the battery using the System test disconnect the battery cables and retest using the Battery Te...

Страница 26: ...it into the Control Module and follow the procedure for setting it to zero 4 Use the UP or DOWN ARROW key to make your selections or press the corresponding numerical key 1 or 2 1 BELOW 250 MILES 2 A...

Страница 27: ...Press NEXT to continue Battery Test Results After the test the analyzer displays a battery decision with an analysis in a series of screens The analysis includes the battery state of health SOH and s...

Страница 28: ...isplay the op tions STARTED and NO START Select STARTED to continue with an alternator test Select NO START to end the test process Starter System Test Results Screen 1 of 2 Average cranking voltage A...

Страница 29: ...a few seconds the analyzer will ask you to turn on the accessory loads It will determine if the charging system is able to provide enough current for the demands of the electrical system IMPORTANT Tur...

Страница 30: ...a built in regulator requiring you to replace the alternator In older vehicles that use external voltage regulators you may need to replace only the voltage regulator The regulator controls voltage ou...

Страница 31: ...2 Select the LOCATION This is determined by whether the battery is in or out of a vehicle when it is tested 1 OUT OF VEHICLE 2 IN VEHICLE Press the NEXT soft key to continue 3 Use the UP or DOWN ARRO...

Страница 32: ...un derside can approximate the battery temperature Press NEXT to continue Additional Test Requirements For a more decisive result the analyzer may ask for additional information or further explore the...

Страница 33: ...erioration accelerates until it finally fails to start the vehicle Before failing the battery may start the vehicle under normal conditions but may not be able to operate in more extreme conditions Ex...

Страница 34: ...ical key to move the dot to the option button of your choice 1 REGULAR FLOODED 2 AGM 3 AGM SPIRAL 4 Press the NEXT soft key Before entering the Power Supply Mode the GR8 will test the battery to deter...

Страница 35: ...lect the BATTERY TYPE or press the corresponding numerical key 1 2 or 3 to move the dot to the option button of your choice 1 REGULAR FLOODED 2 AGM 3 AGM SPIRAL Press the NEXT soft key The BACK soft k...

Страница 36: ...PE or press the corresponding numerical key 1 or 2 to move the dot to the option button of your choice 1 LIMIT CURRENT 2 LIMIT VOLTAGE Press the NEXT soft key The BACK soft key returns you to the Main...

Страница 37: ...enu 6 If the battery is safe to charge the GR8 will begin charging at the selected levels The illustration shows an example of the information displayed during timed charging NOTE If Continuous charge...

Страница 38: ...the results of the Battery and System Tests To print the results select the PRINT soft key To return to the Main Menu press the END key View Test Charger VIEW TEST CHARGER gives you the option of view...

Страница 39: ...time they were cleared by ADMIN 3 LAST 100 LOG Last 100 tests performed by User ID and by UNREG user includes the date and the battery decision GOOD REPLACE etc 4 TOTALS BY DECISION Totals by battery...

Страница 40: ...mponent s housing as ground DMM test leads at the battery terminals NOTE The test requires a complete circuit If you re testing a system with a remote solenoid you can test from the battery to the sol...

Страница 41: ...o print the results select the PRINT soft key To return to the Main Menu press the END key Alternator Circuit The Alternator Circuit Test measures the voltage drop of the alternator circuit 1 SELECT C...

Страница 42: ...d to select the rated amperage of the circuit you are testing The default is 10 A Press the NEXT soft key to continue 3 Connect the positive clamp of the battery test leads to the component s positive...

Страница 43: ...t the DMM test lead to the GR8 s accessories port 2 Select the meter s icon 3 Connect the clamps or probes in the correct polarity red clamp or probe to positive black to negative 4 The meter will aut...

Страница 44: ...cross components such as diodes 1 Connect the probes test lead to the GR8 s accessories port 2 Select the meter s icon 3 Connect the probes in the correct polarity red clamp or probe to positive black...

Страница 45: ...y to return to the CLOCK ADJUST screen Format Use the UP or DOWN ARROW or press the corresponding numerical key 1 or 2 to move the dot to the option button of your choice 1 Select the format of the da...

Страница 46: ...save your changes Shop The SHOP INFO utility allows you to create a header for your printed test results with your business lo cationinformationwhentheAdminoption3 PRINT HEADER is selected page 35 Its...

Страница 47: ...ey or press the correspond ing numerical key to move the dot to the option button of your choice 1 or 2 1 NO USER COUPON PRINTED 2 USER COUPON 2 If you used the ARROW keys press the SAVE soft key to s...

Страница 48: ...ion displays the language option after you turn it on or print results To set your preference 1 Use the UP or DOWN ARROW key or press the correspond ing numerical key 1 2 or 3 to move the dot to the o...

Страница 49: ...the VERSION information screen Reset Defaults This function allows you to reset Administrative options to their original settings It will clear all registered users Table 18 Battery Ratings Option Def...

Страница 50: ...or DOWN ARROW keys to scroll to the method for data entry you want to use 1 MANUAL EDIT 2 DATA CARD Press the NEXT soft key to continue 3 Insert a character by pressing the alphanumeric key asso ciat...

Страница 51: ...E CONNECTION CHECK POLARITY OF SMALL CLAMPS At power up or when reverse connection is made For charger this can only occur at main menu or in a charger test screen Tool will return to state that threw...

Страница 52: ...d will attempt to retest Make sure all vehicle loads are off doors are closed and the ignition is in the off position The GR8 will automatically retest when it no longer detects system noise If the me...

Страница 53: ...e of water and baking soda Periodically clean the clamps using a mixture of baking soda and water or a mild hand soap and a small bristle brush Clean the battery terminals If stud adapters are require...

Страница 54: ...replace the equipment with a remanufactured equipment This limited warranty applies only to the specified equipment and does not cover any other equipment static damage water damage overvoltage damage...

Отзывы: