Chapter 3: Battery Test

Battery Rating Systems

Rating 

System

Description

Range

CCA

Cold Cranking Amps (specified 

by SAE): The amount of current 

a battery can provide at 0 ºF 

(–17.8 ºC).

100 to 3000

CA

Cranking Amps: The amount of 

current a battery can provide at 

32°F (0 ºC).

100 to 3000

MCA

Marine Cranking Amps: The 

amount of current a battery can 

provide at 32°F (0 ºC).

100 to 3000

JIS

Japanese Industrial Standard: 

(shown on a battery as a 

combination of numbers and 

letters.

72 numbers 

from 26A17 

to 245H52

DIN (A) Deutsche Industrie-Norm

100 to 1000

SAE (A) European labeling of CCA

100 to 3000

IEC (A)

International Electrotechnical 

Commission

100 to 1000

EN (A)

Europa-Norm

100 to 1700

7.  Press 

 or 

 to select the BATTERY RATING. Press ENTER.

If you select JIS, the analyzer asks for the JIS part number. 

Scroll to the part number. To increase your scrolling speed, 

hold the 

 or 

 key, or use 

 or 

 to move up or down 

four part numbers at a time. Press ENTER to continue.

8.  Hold the analyzer two inches above the battery case so 

that the IR temperature sensor on the underside of the 

tester can approximate the battery temperature. Press 

NEXT to continue.

Additional Test Requireme

nts and Messages

For a more decisive result the analyzer may ask for additional 

information or further explore the battery’s condition. The 

following messages and instructions may appear before the 

analyzer displays the results.

System Noise Detected

The analyzer has detected computer, ignition noise, or 

parasitic drain, and will attempt to retest. Make sure all vehicle 

loads are off, doors are closed, and the ignition is in the off 

position. The analyzer will automatically retest when it no 

longer detects system noise. If the message reappears:
• 

You may be testing too close to a noise source, such as a 

charger or other high-current device. If so, move away and 

retest.

• 

If  you  are  unable  to  find  the  source  of  the  noise,  fully 

charge the battery and retest. If the message appears after 

recharging, test the battery out of the vehicle.

• 

Disconnect the battery cables and retest.

Unstable Battery Detected

A battery that is weak or that has just been charged may retain 

enough electrical activity to be detected by the analyzer 

and will adversely affect the test results. A fully charged 

battery should stabilize quickly, after which the analyzer 

will automatically retest. Weak batteries should be charged 

and retested. If the battery is fully charged, check the clamp 

connections.

Deep Scan Test

In some cases the analyzer may need conduct a Deep Scan 

Test for a few seconds to determine whether the battery 

should be replaced or if it has a chance to be recovered. 

Voltage Out of Range

The analyzer has detected two 12-volt batteries connected in 

series. Disconnect the batteries and test them individually.

Battery Test Results

  IMPORTANT: To print results the tester must be con-

nected to a battery measuring 11.50 to 16.00 volts.

The tester prints the results before displaying the battery 

decision with an analysis in a series of screens. The analysis 

includes the battery state-of-health (SOH). See the Battery 

Decisions table for an explanation of the various possible 

battery decisions.

  NOTE: 

When the option TRACK CALLS is enabled, the 

tester writes the results to the data card.

Use 

 or 

 to scroll to each screen. To return to the Main 

Menu, press END. If you are performing a System Test, press 

NEXT to continue with the Starter System Test.

Battery 

decision

Measured 

voltage

Selected 

rating

Battery 

temperature

Measured 

CCA 

Содержание EXP-802

Страница 1: ...For testing 6 and 12 volt automotive batteries and 12 and 24 volt charging systems INSTRUCTION MANUAL EXP 803 Battery Electrical Diagnostic Analyzer March 2013 167 000495EN A...

Страница 2: ...blank page behind cover...

Страница 3: ...ages 12 System Noise Detected 12 Unstable Battery Detected 12 Deep Scan Test 12 Voltage Out of Range 12 Battery Test Results 12 State of Health SOH 13 Chapter 4 System Test 14 Battery Test 14 Starter...

Страница 4: ...Power Indicator 25 Replacing the Internal Batteries 25 Clamps 25 Cleaning the Clamps 25 Handling the Test Cables 26 Troubleshooting 26 Problems with the Display 26 The display does not turn on 26 The...

Страница 5: ...start servicing the battery Use caution when working with metallic tools to prevent sparks or short circuits Never lean over a battery when testing charging or jump starting Risk of explosive gases Ne...

Страница 6: ...yzer align the arrow on the cableconnectorwiththe arrows on the analyzer s housing Hold the part of the cable connector as shown and firmly insert the connector into analyzer s six pin receptacle Do n...

Страница 7: ...ows you whether the screen is the top or only screen middle or last in a series Top screen Middle screen Last screen Scroll Box Arrow keys Press the key to move up to the next selectable item or row W...

Страница 8: ...ccession without re entering battery information each time Utility to view and print test results a test counter a data transfer utility and information on the analyzer software version and serial num...

Страница 9: ...bles you to set the language for the display and printed test results You can disable this option in the Admin Menu 1 Use or to select which language should be used on the tester screen 1 ENGLISH 2 ES...

Страница 10: ...When testing side post or Group 31 batteries always use lead terminal adapters provided with the tester do not test at the battery s steel bolts To avoid damage never use a wrench to tighten the adapt...

Страница 11: ...hicle Press NEXT to continue 3 Use or to select the POST TYPE and press NEXT to continue 1 TOP POST 2 SIDE POST 3 JUMP START POST System Test only Press NEXT to continue 4 Use or to select the APPLICA...

Страница 12: ...n The analyzer will automatically retest when it no longer detects system noise If the message reappears You may be testing too close to a noise source such as a charger or other high current device I...

Страница 13: ...BATTERY Return the battery to service GOOD RECHARGE Fully charge the battery and return it to service CHARGE REQUIRED Fully charge the battery using a Midtronics Diagnostic Charger and retest Failure...

Страница 14: ...System Decisions Decision Action CRANKING NORMAL The starter voltage is normal and the battery is fully charged LOW VOLTAGE The starter voltage is low and the battery is fully charged CHARGE BATTERY T...

Страница 15: ...DC voltage range Bar graph showing DC voltage within normal range with loads on and off Graph of diode waveform Peak to peak AC voltage Charging System Decisions Decision Action NO PROBLEMS The system...

Страница 16: ...12 80v 5 For the next few seconds the tester evaluates the battery writes the results to the data card and displays the results starting from the last battery tested To view a previous re sult for a b...

Страница 17: ...e selected battery Select option 2 to print the results of all the bat teries listed by the date and order in which they were test ed Select PRINT 1 INVENTORY BATTERY 2 INVENTORY SUMMARY Totals The TO...

Страница 18: ...the tester boots up and when you print test results ADMIN OPTIONS 1 USER ID User login screen enabled ON 2 UNREG USER Unregistered user accessibility enabled ON 3 PRINTER HEADER Prints address header...

Страница 19: ...nes of your shop information Users The USERS utility allows you to create and edit a USER ID with 1 to 7 alphanumeric characters and link it to a test counter It also allows you to delete a USER ID an...

Страница 20: ...me Backlight time is from 0 to 30 seconds To change it 1 Use or to select BACKLIGHT TIME CONTRAST LEVEL 10 BACKLIGHT TIME 60 2 Press ADJUST to display the option s numerical scroll box 15 SEC 3 Press...

Страница 21: ...ackets that define the data NOTE To avoid corrupting the file copy rather than move the file to your PC The default setting for the utility is OFF 1 To change the setting use or to make your selection...

Страница 22: ...ill not clear the lifetime test total avail able in the VERSION information screen Reset Defaults This function allows you to reset Administrative options to their original settings It will clear all...

Страница 23: ...diameter Replacement rolls are available at most office supply stores NOTE Due to production variances some paper roll diameters may be too large Please remove paper from roll to recommended 17 8 inc...

Страница 24: ...ile These data fields will be displayed as the header row in your spreadsheet application STORE ID Entered by user TIME Time of test DATE Date of test LOCATION Tested in vehicle or out of vehicle MEAS...

Страница 25: ...b 3 Lift the door at the tab and place it aside 4 Remove the discharged batteries 5 Insert new batteries as shown Make sure the positive and negative terminals are positioned correctly 6 Reposition th...

Страница 26: ...ve been abused are not covered under the Midtronics warranty If an inspection or a change in test results indicate that the test cables need to be replaced please call Midtronics Customer Service at 1...

Страница 27: ...efore entering it into the Battery Diagnostic Station Header Template Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 Line 9 Line 10 Line 11 Line 12 Coupon Template To help you edit and center...

Страница 28: ...or to modify the cable assembly SERVICE To obtain service contact Midtronics at 1 630 323 2800 Have your model and serial numbers ready This first step is critical as we will trouble shoot the proble...

Отзывы: