35
10.3 Key parts checking.
10.3.1. Compressor checking
(Model: DA89X1C-20EZ).
Measure the resistance value of each winding by using the multi-meter.
10.3.2 Outdoor Fan Motor
(Model: YDK24-6P).
Measure the resistance value of each winding by using the multi-meter.
10.3.3 Indoor Fan Motor
(Model: RPG20D).
Measure the resistance value of each winding
by
using the multi-meter.
10.3.4 Step Motor
(Model: MP2835). Measure the resistance
value
of each winding by using the multi-meter.
Position
Resistance Value
Blue - Red
Blue - Black
Red - Blue
0.71
Ω
(20
Ԩ
)
Position
Resistance Value
Black - Red
418
Ω
±8% (20
Ԩ
)
Blue - Red
277
Ω
±8% (20
Ԩ
)
Yellow - Blue
277
Ω
±8% (20
Ԩ
)
Position
Resistance Value
Black - Red
400
Ω
±8% (20
Ԩ
)
White - Black
383
Ω
±8% (20
Ԩ
)
Position
Resistance Value
Blue - Red
Pink - Orange
Pink - Yellow
200
Ω
±7% (25
Ԩ
)
Yellow - Red
Содержание MS9A-09HRDN1-QC2
Страница 3: ...10 1 Indoor Unit Error Display 31 10 2 Diagnosis and Solution 32 10 3 Key parts checking 40...
Страница 10: ...7 3 2 Outdoor Unit MOR 09 12HDN1 QC2...
Страница 12: ...9 5 Refrigerant cycle diagram...
Страница 13: ...10 6 Wiring diagram 6 1 Indoor Unit MS9A 09 12HRDN1 QC2...
Страница 14: ...11 6 2 Outdoor Unit MOR 09 12HDN1 QC2...
Страница 40: ...37...