28
Δ
T=T1-Ts Running
mode
Δ
T
>
1
℃
Cooling
-
1≤
Δ
T
≤
1
℃
Fan-only
Δ
T
<
-1
℃
Heating
9.8.2 Indoor fan will choose auto speed of relevant mode.
9.8.3 If the machine switches mode between heating and cooling, compressor will keep stopping for 15 minutes and
then rechoose mode according to
Δ
T.
9.8.4 If the setting temperature is modified, the machine will rechoose running function.
9.9 Forced operation function
9.9.1 Forced cooling and auto function can carry out with a touch button. In these two modes, the machine can be
changed by remote controller to any other mode at any moment.
9.9.2 When the machine is off, pressing the touch button once, the unit will enter forced auto mode. When the
machine is off, pressing the touch button twice within 5s, the unit will enter forced cooling mode. When the unit is
running at forced auto or forced cooling mode, pressing the touch button continuously, the unit will be turned off.
9.9.3 In forced operation mode, all general protections is available.
9.9.4 In forced cooling mode, the unit will run with fixed frequency F2 at low speed. 30 minutes later, the unit will turn
to normal auto mode with setting temperature 24
℃
.
9.9.5 In forced auto mode, the unit will run with setting temperature 24
℃
.
9.10 Action of 4-way valve
In heating, fan-only, standby or turning off mode, 4-way valve is off, while in cooling\drying and forced cooling
mode 4-way valve is on. If the machine changes operation mode, 4-way valve will be delayed off 2 minutes after
compressor stop. For defrosting, please refer to the passage “defrosting mode”.
9.11 Two speeds outdoor fan function
9.11.1 Outdoor fan starts at the same time with compressor, but stops 30 seconds later than compressor ‘s stop.
9.11.2 Outdoor fan action in heating mode(including heating in auto mode).
9.11.3 Outdoor fan action in cooling & drying mode(including cooling in auto & forced mode).
Please refer to the pic. above.
Outdoor fan action in cooling & drying mode
(including cooling in auto & forced mode).
17
15
℃
out
door t
empera
ture
low
high
out
door f
an spee
d
Outdoor fan action in heating mode
(including heating in auto mode).
22
20
℃
out
door t
empera
ture
high
low
out
door f
an spee
d
Содержание MS9A-09HRDN1-QC2
Страница 3: ...10 1 Indoor Unit Error Display 31 10 2 Diagnosis and Solution 32 10 3 Key parts checking 40...
Страница 10: ...7 3 2 Outdoor Unit MOR 09 12HDN1 QC2...
Страница 12: ...9 5 Refrigerant cycle diagram...
Страница 13: ...10 6 Wiring diagram 6 1 Indoor Unit MS9A 09 12HRDN1 QC2...
Страница 14: ...11 6 2 Outdoor Unit MOR 09 12HDN1 QC2...
Страница 40: ...37...