9.12 Timer function
9.12.1 Timing range is 24 hours, and the minimum resolution is 15 minutes.
9.12.2 Timer on. After turning off, the machine will turn on automatically when reaching the setting time.
9.12.3 Timer off. After turning on, the machine will turn off automatically when reaching the setting time.
9.12.4 Timer on/off. After turning off, the machine will turn on automatically when reaching the setting “on” time,
and then turn off automatically when reaching the setting “off” time.
9.12.5 Timer off/on. After turning on, the machine will turn off automatically when reaching the setting “off” time,
and then turn on automatically when reaching the setting “on” time.
9.12.6 The tolerance of timer is 1 minute per hour.
9.13 Sleep function mode
9.13.1 Operation time in sleep mode is 7 hours. After 7 hours the machine quits this mode and turns off.
9.13.2 Sleep function is available in cooling, heating and auto mode .
9.13.3 Operation process in sleep mode is as follow:
1) After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode.
2) When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hour later the
rising stops and indoor fan is fixed as low speed.
3) When heating, the setting temperature descends 1
℃
(be lower than 30
℃
) every one hour, 2 hour later
the descending stops and indoor fan is fixed as low speed, and anti-cold-wind is available.
9.14 Auto-Restart function
The indoor unit is equipped with auto-restart function. In case of a sudden power failure, the setting conditions
before the power failure will be restored. The unit will resume the previous operation setting automatically after 3 minutes
when power returns.
9.15 Ionizer/Plasma dust collector function(optional)
The indoor unit is equipped with Ionizer/Plasma, which is controlled by the CLEAN AIR button on the remote
controller. Press the CLEAN AIR button to activate the function while the unit is turned on, press it again to stop
the function. Ionizer/Plasma will be turned off automatically if indoor fan stops running due to malfunctions or
anti-cold-wind. When indoor fan restarts after malfunctions being eliminated and anti-cold-wind being released,
Ionizer/Plasma will be available again.
9.16 Outdoor chassis heating cable (optional)
Heating cable is fixed on outdoor chassis to help deicing and to avoid freezing. The heating cable’s power is 85W,
rated voltage is 220V-240V, and is controlled by the program. If outdoor temperature is lower than 5
℃
, the heating
cable will begin to work. If outdoor temperature is higher than 15
℃
, the heating cable will stop working.
Содержание MS9A-09HRDN1-QC2
Страница 3: ...10 1 Indoor Unit Error Display 31 10 2 Diagnosis and Solution 32 10 3 Key parts checking 40...
Страница 10: ...7 3 2 Outdoor Unit MOR 09 12HDN1 QC2...
Страница 12: ...9 5 Refrigerant cycle diagram...
Страница 13: ...10 6 Wiring diagram 6 1 Indoor Unit MS9A 09 12HRDN1 QC2...
Страница 14: ...11 6 2 Outdoor Unit MOR 09 12HDN1 QC2...
Страница 40: ...37...