Page i
Installation &
Maintenance Guide
Midea Heat Pump Water Heater - 170 Litre
Страница 1: ...Page i Installation Maintenance Guide Midea Heat Pump Water Heater 170 Litre ...
Страница 2: ... heater to prevent water temperatures going to the home exceeding a pre set safe maximum A tempering valve must be connected to the hot water outlet line from the water heater The valve must be fitted by an authorised plumber at the time of installation or in retrofitting to existing systems Care should be taken to avoid coming into contact with any pipe work or fixtures associated with the water ...
Страница 3: ...ety Information 3 Section 3 Before Installation 4 Section 4 System Installation 5 8 Section 5 System Commissioning 9 10 Section 6 System Operation 11 14 Section 7 System Troubleshooting 15 17 Section 8 System Maintenance 18 Section 9 Warranty 19 GUIDE CONTENTS ...
Страница 4: ...CONTROL BOX POWER CONNECT BOX COVER COMPRESSOR DISPLAY ANODE ROD COVER ATCO TCO ELECTRICAL ELEMENT COVER NOTE All pictures in this manual are for explanation purpose only They may different from the actual unit 978 PTR CONNECTION 978 HOT OUTLET 685 COLD INLET 1580 HEIGHT 568 WIDTH 1215 ELECTRICAL ENTRY MIN 700 SUPPORT BASE MIN 700 SUPPORT BASE PRODUCT INFORMATION SCHEMATICS 1 1 1 System Schematics...
Страница 5: ...nnector diameter DN20 PTR valve connector diameter DN20 Maximum pressure 1000kPa Exchanger air Side Material Hydrophilic aluminium fin inner groove copper tube Motor power 40W Air inlet outlet Air in from Sides Air out from Rear Fusible link type T20A 250VAC Refrigerant R134a 800g Dimension Ø568 1580mm Water tank capacity 170L Net weight 90kg The test conditions 1 Test temperature 15 12 C DB WB 2 ...
Страница 6: ...he unit in an area protected from the wind The PTR Valve should be operated every 6 month to make sure that there is no restriction of the valve Please beware of hot water being expelled from the valve The drainage pipe should be well insulated in order to prevent water inside pipe from freezing in cold weather CAUTION The earthing pole must be well grounded Make sure that any power supply socket ...
Страница 7: ...be installed on a metal part of the building make sure the electrical insulation meets the relevant local standard 12 Securely fixing the unit will assist in avoiding unwanted noise and or vibration CAUTION Consideration must also be made in regards to the ambient air temperature Heat pump economy mode operates between ambient air temperatures of 5 C and 43 C Temperatures below this range will rel...
Страница 8: ... and durable WARNING Do not dismantle the PTR Valve Do not block off the Drainage pipe it may cause explosion and or injury 4 2 Installation position requirement Install the unit with suitable clearance for air flow and plumbing access refer to options below OPTION 1 Front On DISPLAY 150 AIR OUTLET 600 AIR OUTLET WALL W OPTION 2 Side DISPLAY 150 AIR OUTLET 600 DISPLAY AIR OUTLET 600 WALL WALL Posi...
Страница 9: ...ockwise direction Then simply lift up to remove H HOT PIPE TO TEMP VALVE COLD PIPE INC NON RETURN VALVE Wire electrics by feeding the cable through one of the openings on the under face of the upper section of the unit and up to the electrical compartment Remove the electrical compartment cover by releasing the two screws Then connect the wires accordingly Where possible terminate the electrical c...
Страница 10: ...lorine i e elements found in aerosol sprays detergents bleaches cleaning solvents air fresheners paint varnish removers refrigerants and many other commercial and household products The location is free from any excessive dust if so more frequent cleaning will be required by the user 4 5 2 Water System Piping PTR valve Temperature and pressure relief valve is properly installed with a discharge pi...
Страница 11: ...Page 8 4 6 Final Installation Below is an example of a proper heat pump installation along with all plumbing and electrical connections ...
Страница 12: ...15 20 25 30 32 35 40 43 Capacity W Ambient temp 15 45 15 55 15 65 1 2 3 4 5 6 7 5 7 15 20 25 30 32 35 40 43 COP W W Ambient temp 15 45 15 55 15 65 0 00 00 2 24 00 4 48 00 7 12 00 9 36 00 12 00 00 14 24 00 5 7 15 20 25 30 32 35 40 43 Time h Ambient temp 15 45 15 55 15 65 Ambient Temperature vs Capacity 500 1000 1500 2000 2500 3000 5 7 15 20 25 30 32 35 40 43 Capacity W Ambient temp 15 45 15 55 15 6...
Страница 13: ...ressor and E heater will be automatically shut off or turned on by the TCO Thermal Cut Out and the ATCO Automatic Thermal Cut Out If the water temperature is higher than 78 C the ATCO will automatically shut off the power to the compressor and E heater and turn it on if the temperature falls below 68 C If the water temperature is higher than 85 C the TCO will automatically shut off the power to th...
Страница 14: ...t was not operational at the time the power was turned off the flashing fill water icon will be displayed on screen indicating to fill tank before making it operational Once the tank is full simply unlock the control panel and press the ON OFF button changing the flashing fill water icon to a solid icon Pressing the ON OFF button once again will turn the icon off Note The fill water icon will not ...
Страница 15: ... display the desired temperature When in error or protection mode the water temperature setting will display the relevant code When in query mode the water temperature setting will display the relevant running parameter 14 Temp unit When the Water temperature setting is displaying a temperature the Degrees Celsius icon will be displayed on screen 15 Set Temp When setting the units desired temperat...
Страница 16: ...tton When setting the clock timer to increase the time press the UP ARROW button Decrease Down To decrease the temperature unlock the control panel and proceed to press the DOWN ARROW button When setting the clock timer to decrease the time press the DOWN ARROW button Setting the 24 Hour Clock If the intention is to use timers with the unit the initial clock time will need to be set To set the cur...
Страница 17: ... value in 10 minute increments Press the TIME ON button again to confirm minute TIME ON setting To set the TIME OFF value press the TIME OFF button The TIME OFF clock will appear below the normal clock to the right of the TIME ON clock with the hour value flashing Use the ARROW buttons to set the correct hour value Press the TIME OFF button again to confirm hour setting The minute value will flash...
Страница 18: ...h to set timers for your system please refer to section 6 of this guide on how to do so 3 The unit has been switched off Check the unit and ensure the red LED light is showing If not unlock the controller by holding the cancel button for 3 seconds the lock icon will disappear from the display screen Then simply press the on off button and now the red LED light should be lit 4 The connected power i...
Страница 19: ...t is outside a bedroom the noise is too much during the night If the location of your heat pump unit is in close proximity to a bedroom and your hot water usage pattern is consistently high at night then the heat pump may operate during the night During the quietness of night you may hear the quiet hum of the heat pump that may cause you some concern If your hot water usage pattern is consistently...
Страница 20: ...it E9 Compressor suction temperature sensor TH error The connection between sensor and PCB is broken or the sensor has experienced an issue Contact a qualified person to service the unit P8 E heater open circuit protection IEH Current difference E heater on e heater off 1A The E heater has been broken or there is a wiring connection issue Contact a qualified person to service the unit P2 High disc...
Страница 21: ... regularly to maintain efficient performance Turn off the power Close the cold water inlet valve open a hot water tap Use a flexible pipe to connect the drain port to a suitable sewage drain Note The min heat resistance of the drain pipe must not be less than 93 if the drain pipe does not meet the requirement please open the cold water inlet valve open a hot water tap until the temperature of the ...
Страница 22: ...is warranty If any component of the heat pump has been installed repaired repositioned or modified by a person other than an appropriately qualified person approved by Chromagen in accordance with the installation and maintenance instructions and relevant local and statutory requirements For loss or damage caused by a fault or defect in the installation of the heat pump If corrosion has occurred b...
Страница 23: ...tails see reverse side for further instruction Images shown are representative only Product specifications subject to change without notice For the latest product details and specifications please visit our website www chromagen com au Chromagen Australia source a range of high quality products components from a global marketplace to provide Australian consumers with outstanding energy efficient a...
Страница 24: ...e in an envelope and address as follows Chromagen Australia Pty Ltd 17 23 Redwood Drive Dingley Village VIC 3172 Or alternatively register your warranty online at www chromagen com au warranty chromagen com au 1300 367 565 Hot Water Solutions Solar Power Systems Kitchen Appliances Air Conditioning Another Hot Water Solution by ...