250
f)
Frame Type 1 - Start + Address 7 + Read/Write + Ackno Data; if all bits in the frame type match,
trigger on read/write frames in 7-bit addressing mode on the 17th clock edge.
Frame type 1 operation method: Select values after the address/data, click values after the address/data on
the touch screen, and modify them on the pop-up virtual soft keyboard.
g)
Frame type 2 — Start + Address 7 + Read/Write + Ackno Data 1 + Ackno Data 2; trigger
on read/write frames in 7-bit addressing mode on the 26th clock edge if all bits in the frame type match.
The operation method of configuring frame type 2 is the same as frame type 1, and will not be repeated
here.
h)
EEPROM data read - When the read operation which contains 1010xxx control byte of the EEPROM
appears on the bus and the Ack bit is correct, then the read data can be captured. If the captured data and
the set data match the set relationship condition, trigger on the clock edge of Ack bit after the data byte.
After selecting “EEPROM Data Read”, click the relationship by “=” “ >” “<” “ ≠”, and the setting method
is the same as the address field.
i)
10-bit write frame - Trigger on 10-bit write frame on the 26th clock edge if all bits in the pattern match.
Содержание Smart Series
Страница 1: ......
Страница 2: ...Version Info Version Date Remarks V2 0 2019 10 ...
Страница 25: ...Chapter 2 Quick Start Guide of Oscilloscope 11 2 3 Side Panel Figure 2 2 Side Panel ...
Страница 27: ...Chapter 2 Quick Start Guide of Oscilloscope 13 2 5 Front Panel Figure 2 4 Front Panel of Tablet Oscilloscope ...
Страница 30: ...16 Figure 2 5 Oscilloscope Interface Display ...
Страница 51: ...Chapter 3 Operate the Oscilloscope with Buttons 37 Figure 3 1 Button Areas ...
Страница 61: ...Chapter 4 Horizontal System 47 Figure 4 1 Horizontal system ...
Страница 82: ...68 Figure 5 4 Channel Open Close and Switching ...
Страница 88: ...74 Figure 5 7 DC Coupling Figure 5 8 AC Coupling ...
Страница 126: ...112 Figure 6 21 Trigger Level Adjustment Trigger pulse width time can be set as 8ns 10s ...
Страница 150: ...136 Figure 7 2 Pull up Menu Figure 7 3 All Measurements ...
Страница 159: ...Chapter 7 Analysis System 145 Figure 7 8 Frequency Meter Measurement Menu Open Figure 7 9 Frequency Meter Measurement ...
Страница 161: ...Chapter 7 Analysis System 147 Figure 7 10 Cursor Measurement Description ...
Страница 168: ...154 Figure 8 1 Screen Capture Please refer to 13 6 Picture View for details on viewing pictures ...
Страница 176: ...162 Figure 8 5 Delete Reference Files CSV files CSV file structure ...
Страница 190: ...176 Figure 9 4 Spectrum Amplitude as V Hz Adjust FFT waveforms Waveform position ...
Страница 236: ...222 Figure 12 8 UART Graphic Interface UART graphic interface description 1 Trigger position 2 Trigger type ...
Страница 324: ...310 Figure 14 6 Android APP Figure 14 7 Successful Connection of Android APP ...
Страница 336: ...322 Figure 15 3 Decode Functions Installed ...
Страница 353: ...Annex 339 Optional accessories 1 Oscilloscope suitcase handbag 2 Battery 3 Leather carry strap 4 High voltage probe ...