Alarm
Affected
Component
Description
LED to
RED
Alarm
Code
Severity
STM LP-
UNEQ lkm
IDU
The SDH/SONET Mux/Demux
LP number ‘x’ is Unequipped.
Fault detection via polling of
LP_UNEQ_T bit in STM-1 Core.
Where ‘lkm’ is the LP index as
LKM numbering. Alternate
detection via Interrupt enabled in
STM-1 core.
N/A
Solid
Info
STM LP-TIM
lkm
IDU
The SDH/SONET Mux/Demux
LP number ‘x’ has a Trace
Identifier Mismatch. Fault
detection via polling of
LP_TM_TIM_T bit in STM-1
Core. Where ‘lkm’ is the LP
index as LKM numbering.
Alternate detection via Interrupt
enabled in STM-1 core.
N/A
Solid
Major
STM LP-REI
lkm
IDU
The SDH/SONET Mux/Demux
LP number ‘x’ has a Remote
Error Indication. Fault detection
via polling of LP_REI_T bit in
STM-1 Core. Where ‘lkm’ is the
LP index as LKM numbering.
Alternate detection via Interrupt
enabled in STM-1 core.
N/A
Solid
Critical
STM LP-RDI
lkm
IDU
The SDH/SONET Mux/Demux
LP number ‘x’ has a Remote
Defect Indication. Fault
detection via polling of
LP_RDI_T bit in STM-1 Core.
Where ‘lkm’ is the LP index as
LKM numbering. Alternate
detection via Interrupt enabled in
STM-1 core.
N/A
Solid
Critical
STM LP-PLM
lkm
IDU
The SDH/SONET Mux/Demux
LP number ‘x’ has a Path
Identifier Mismatch. Fault
detection via polling of
LP_PLM_T bit in STM-1 Core.
Where ‘lkm’ is the LP index as
LKM numbering. Alternate
detection via Interrupt enabled in
STM-1 core.
N/A
Solid
Critical