User Reference and Installation Guide
6-5
© 2006 Microwave Data Systems Inc. All Rights Reserved.
MDS FOUR.9 Series
05-4561A01, Rev. A
Alarm
Affected
Component
Description
LED to
RED
Alarm
Code
Severity
Framer
Initialization
Timeout
StdIO
There is an Initialization wait for
Framer to turn ON the Framer
Receiver side after turning ON
the Modem/ODU. Fault
detection via polling. Poll only
after timeout to detect.
Standard
I/O
43
Critical
Mini I/O Card
Removed
MiniIO
The Mini I/O card has been
removed from the IDU (only if
Mini I/O card has been enabled
for use). Fault detection via
card-detect logic.
Standard
I/O
46
Critical
Mini I/O Card
Installed
MiniIO
The Mini I/O card has been
installed into the IDU (only if
Mini I/O card is noted enabled
for use). Fault detection via
card-detect logic. Alarm is
cleared after 5 minutes.
Standard
I/O
47
Info
Optional I/O
Card
Removed
OptIO
The Optional I/O card has been
removed from the IDU (only if
the Optional I/O card has been
enabled for use). Fault detection
via card-detect logic.
N/A
26
Critical
Optional I/O
Card Installed
OptIO
The Optional I/O card has been
installed into the IDU (only if the
Optional I/O card is not enabled
for use). Fault detection via
card-detect logic. Alarm is
cleared after 5 minutes.
Optional
I/O
27