User Reference and Installation Guide
3-6
© 2006 Microwave Data Systems Inc. All Rights Reserved.
MDS FOUR.9 Series
05-4561A01, Rev. A
•
Confirm
•
Line of sight for each link
•
ODU mounting locations
•
Site equipment locations
•
Cable routes
•
Any other potential RF sources
•
Prepare site drawings and record site information
3.6.1
Preparing for a Site Evaluation
The following tools are required to perform a site evaluation:
•
RF and network design diagrams (as required)
•
Binoculars
•
Global positioning system (GPS) or range finder
•
Compass
•
Measuring tape and/or wheel
•
Digital camera
•
Area map
•
Aerial photograph (if available)
•
List of potential installation sites (“targeted buildings”)
The following tasks must be completed prior to performing a site evaluation:
•
Prepare the initial network design by performing the following:
•
Identify potential buildings by identifying targeted customers (applicable if you’re a service
provider)
•
Identify potential links by selecting buildings based on the high probability of line of sight
•
Arrange for access with the facility personnel into the buildings, equipment rooms, and
architectural plans to become familiar with the location of all ducts, risers, etc.
Содержание FOUR.9 Series
Страница 2: ......