MDS 05-2708A01, Rev. B
MDS TransNET 900 I&O Guide
29
If data buffering is
ON
, the radio will operate in a seamless mode. That is, data
bytes will be sent over the air as quickly as possible, but the receiver will
buffer the data until the entire packet has been collected. The delay introduced
by data buffering is variable and depends on message size and the number of
retransmissions required, but the radio will not create any gaps in the output
data stream. This mode of operation is required for protocols such as
MODBUS™ that do not allow gaps in their data transmission.
Seamless mode (
BUFF ON
) is intended only for applications where the
message size is 256 characters or less. Enforcement of this rule is left up to
the user. If more than 256 characters are transmitted data delivery will not be
seamless and data may be lost.
Changes to the
BUFF
setting may only be made at the master radio. This is
because the master radio broadcasts the buffer setting for the entire network.
At remote radios, the buffer setting may be read when the radio is in
synchronization with the master, but it may not be changed.
CODE [NONE, 1…255]
The
CODE
command is used to select or display the security/encryption
setting in the radio.
The default is
CODE NONE
. Setting
CODE
to a value other than
NONE
provides an extra level security beyond that provided by the Network Address
(
ADDR
). The disadvantage is increased complexity in managing the network.
The
CODE
command takes an argument
1…255,
or “
NONE
”. Entering
CODE
without an argument will display either “
NONE
” or “
ACTIVE
”.
ACTIVE
means that security/encryption has been enabled, but the radio will not
display the security argument.
When a
CODE
value is active, all radios in the system must use the same code
value. If the code value is not properly programmed, a remote radio will not
synchronize with the master.
CAUTION: Record the
CODE
value and store it in a safe place. If the code is
later forgotten, and a unit is to be added to the system, all radios in the
network must be set to
NONE
and then reprogrammed to a new value.
CTS [0–255]
The
CTS
(clear-to-send) command sets or displays the timer value associated
with the CTS line response. The command parameter ranges from 0 to 255
milliseconds.
For DCE operation, the timer specifies how long to wait after the RTS line
goes high before asserting the CTS line. A timer value of zero means that the
CTS line will be asserted immediately following the assertion of RTS.
For CTS Key operation (see the
DEVICE
command), the timer specifies how
long to wait after asserting the CTS line before sending data out the
DATA
port. A timer value of zero means that data will be sent out the data port
without imposing a key-up delay. (Other delays may be in effect from other
radio operating parameters.)
Содержание EL805
Страница 8: ...vi MDS TransNET 900 I O Guide MDS 05 2708A01 Rev B RXD TXD SYN C PWR...
Страница 66: ...58 MDS TransNET 900 I O Guide MDS 05 2708A01 Rev B RXD TXD SYN C PWR...
Страница 70: ...G 4 MDS TransNET 900 I O Guide MDS 05 2708A01 Rev B RXD TXD SYN C PWR...
Страница 76: ...RXD TXD SYN C PWR...