MDS 05-2708A01, Rev. B
MDS TransNET 900 I&O Guide
27
6.3 Detailed Command Descriptions
The essential commands for most applications are Network Address (
ADDR
),
Mode (
MODE
), and Baud Rate (
BAUD
). However, proper use of the additional
commands allows you to tailor the transceiver for a specific use, or to conduct
basic diagnostics on the radio. This section gives more detailed information
for the commands listed above in section
Most of the commands below can be used in two ways. First, you can type
only the command name (for example,
ADDR
) to view the currently
programmed data. Second, you can set or change the existing data by typing
the command, followed by a space, and then the desired entry (for example,
ADDR 1234
). In the list below, allowable programming variables, if any, are
shown in brackets [ ] following the command name.
ADDR [1–65000]
This command sets or displays the radio’s network address. The network
address can range from 1 to 65000.
A network address must be programmed at the time of installation and must
be common across each radio in a given network. Radios are typically
shipped with the network address unprogrammed, causing the address to
display as
NONE
. If the address is not set (or is set to a wrong value) it leaves
the system in an invalid state, preventing operation and generating an alarm.
NOTE:
It is recommended that the last four digits of the master radio’s serial number
be used for the network address. This helps avoid conflicts with other Trans-
NET 900 users.
Table 9. Diagnostic and Test Functions
Command
Description
Enables the transmitter test.
(Radio must be in Setup mode.)
Turns off the transmitter test.
(Radio must be in Setup mode.)
Set/display transmit test frequency.
(Radio must be in Setup mode.)
Set/display receive test frequency.
(Radio must be in Setup mode.)
Enables Setup mode. Times out after 10 min-
utes. Press “Q” to quit.
Zone data statistics
Clears the Zone Data log