Microsemi Proprietary and Confidential. LX3301A/LX3302A Auto Calibration User Guide Revision 1.0

22

Microsemi Corporate Headquarters
One Enterprise, Aliso Viejo,
CA 92656 USA
Within the USA: +1 (800) 713-4113
Outside the USA: +1 (949) 380-6100
Fax: +1 (949) 215-4996
Email: [email protected]
www.microsemi.com

© 2018 Microsemi Corporation. All rights reserved. Microsemi and the 
Microsemi logo are trademarks of Microsemi Corporation. All other 
trademarks and service marks are the property of their respective owners.

Microsemi makes no warranty, representation, or guarantee regarding the information contained herein or the suitability of its products and services 
for  any  particular  purpose,  nor  does  Microsemi  assume  any  liability  whatsoever  arising  out  of  the  application  or  use  of  any  product  or  circuit.  The 
products sold hereunder and any other products sold by Microsemi have been subject to limited testing and should not be used in conjunction with 
mission-critical equipment or applications. Any performance specifications are believed to be reliable but are not verified, and Buyer must conduct and 
complete all performance and other testing of the products, alone and together with, or installed in, any end-products. Buyer shall not rely on any data 
and  performance  specifications  or  parameters  provided  by  Microsemi.  It  is  the  Buyer's  responsibility  to  independently  determine  suitability  of  any 
products and to test and verify the same. The information provided by Microsemi hereunder is provided "as is, where is" and with all faults, and the 
entire risk associated with such information is entirely with the Buyer. Microsemi does not grant, explicitly or implicitly, to any party any patent rights, 
licenses, or any other IP rights, whether with regard to such information itself or anything described by such information. Information provided in this 
document is proprietary to Microsemi, and Microsemi reserves the right to make any changes to the information in this document or to any products 
and services at any time without notice.

Microsemi  Corporation  (Nasdaq:  MSCC)  offers  a  comprehensive  portfolio  of  semiconductor  and  system  solutions  for  aerospace  &  defense, 
communications,  data  center  and  industrial  markets.  Products  include  high-performance  and  radiation-hardened  analog  mixed-signal  integrated 
circuits,  FPGAs,  SoCs  and  ASICs;  power  management  products;  timing  and  synchronization  devices  and  precise  time  solutions,  setting  the  world's 
standard for time; voice processing devices; RF solutions; discrete components; enterprise storage and communication solutions; security technologies 
and  scalable  anti-tamper  products;  Ethernet  solutions;  Power-over-Ethernet  ICs  and  midspans;  as  well  as  custom  design  capabilities  and  services. 
Microsemi is headquartered in Aliso Viejo, California, and has approximately 4,800 employees globally. Learn more at www.microsemi.com.

MSCC-0236-UG-01000-1.0-0518

Содержание LX3301A

Страница 1: ...LX3301A LX3302A Auto Calibration User Guide Preliminary May 2018...

Страница 2: ...Data Capture Preparation Using LX3302A 9 3 4 Data Validation 12 4 Calibration Using IPCE 13 4 1 Loading Data EEPROM into IPCE 13 4 2 Example Data and EEPROM Parameters Loaded 14 4 3 Calibration Condit...

Страница 3: ...on 1 0 1 1 Revision History The revision history describes the changes that were implemented in the document The changes are listed by revision starting with the most current publication 1 1 Revision...

Страница 4: ...stall and validate the software for the LX3301A LX3302A device 1 Connect the dongle to the computer 2 Connect the sensor PCB to the dongle 3 Place your target at a desired air gap The first three step...

Страница 5: ...ion Environment IPCE as shown Figure 2 Launch IPCE 6 Verify that the port has opened as shown Figure 3 Verify Port Has Opened Note If it cannot recognize the dongle then install the driver provided us...

Страница 6: ...tly If the result is as shown in the following three images then communication has not been done correctly Note Place the target with proper air gap distance if it won t read EEPROM correctly Then try...

Страница 7: ...is not connected or AOUT IO3 is stuck high All data is 0000 Place the target in the proper position or fix AOUT IO3 shorted GND Figure 6 Example of IC Detects Fault or AOUT IO3 Stuck at 0 V The follow...

Страница 8: ...Confidential LX3301A LX3302A Auto Calibration User Guide Revision 1 0 6 8 Use the default EEPROM data and write this default EEPROM data to the chip as shown in the following image Figure 8 Write Def...

Страница 9: ...nalog data Figure 10 Data Format for Analog Data SP position Start point position on the data target position See the red arrow EP position End point position on the data See the blue arrow SP AOUT V...

Страница 10: ...m 0 5 V 20 mm negative slope SP_AOUT 0 5 V EP_AOUT 4 5 SP position 20 EP position 3 Figure 11 Data Format for Analog The following image shows the data format for PWM data Figure 12 Data Format for PW...

Страница 11: ...How to Capture Data Using IPCE Manually If data cannot be captured by a motorized automatic system then it can be done manually using IPCE A position measurement tool is required to get an accurate p...

Страница 12: ...re Configuration 2 In the tab check IO2 and IO3 to see the measurements as shown Sensor measurement Figure 16 Sensor Measurements Tab 3 Press to record the data Move the target to the next position an...

Страница 13: ...Press the button if data is captured by IPCE Save Datalog Figure 17 Update Target Output After completing a run with default parameter save all the data in one of the templates shown previously or if...

Страница 14: ...libration User Guide Revision 1 0 12 3 4 Data Validation After data collection check if the data is valid to use In Excel plot and check that the curve is not intermittent and does not have drops The...

Страница 15: ...as shown Load Bench Data From File Figure 20 Load Bench Data From File 2 Select the data file captured and prepared as given data format Excel 3 When the following window appears click OK Figure 21 Su...

Страница 16: ...23 Example Loaded Data and EEProm Para Loaded 4 3 Calibration Condition Settings The following image shows the calibration condition settings The example given is 35 mV This means that any given posit...

Страница 17: ...from the file is loaded phase and calibration can be completed 1 Check the box for both and linear Cal phase Cal 2 Click Auto Calibration Figure 25 Auto Calibration Calibration is complete The result...

Страница 18: ...l phase Cal 2 Press Then the new values of SSIN SCOS and GMTCH should appear Auto Calibration 3 Burn this into the IC by write Eeprom to chip Figure 27 Auto Calibration of Phase 5 Click to open the ma...

Страница 19: ...le simulation Figure 29 Example Simulation 4 6 Save Calibrated Result into EEPROM The following steps describe how to save the calibrated result into EEPROM 1 When the auto calibration simulation resu...

Страница 20: ...ed rate as shown Figure 33 Refresh 6 Click write eeprom to chip 7 Click Then select the proper file save location and type in the filename to Save EEProm Data to File store for example SN_01_Final_eep...

Страница 21: ...ers 6 Select the Sensor measurement tab to view the measurements 5 2 Collect Measurements with Default Parameters At this moment in calibration measurement data needs to be collected using default par...

Страница 22: ...0 20 The following image shows how to set the calibration condition in the datalog file Figure 35 Calibration Condition Setting The following image shows an example datafile with a negative slope Figu...

Страница 23: ...tocal Figure 37 Example of Post Autocal 5 3 Save EEPROM Data to File After you have saved the default parameters file save the EEPROM data to file Save the current EEPROM parameters You can do this by...

Страница 24: ...sibility to independently determine suitability of any products and to test and verify the same The information provided by Microsemi hereunder is provided as is where is and with all faults and the e...