Quadrus MINI Imager User’s Manual
10-21
Camera and IP Setup
Cycle Max
Cycle Step
Adaptive Contrast Percent
Definition:
Ending value of the cycle mode.
Serial Cmd:
<
K512,
threshold mode,fixed threshold value,cycle min,
cycle max
,cycle
step,adaptive contrast percent
>
Default:
255
Options:
0 to 255
Important: Cycle Max must be a greater numerical value than Cycle Min.
Definition:
The numerical value of a single cycle mode increment.
Serial Cmd:
<
K512,
threshold mode,fixed threshold value,cycle min,cycle max,
cycle
step
,adaptive contrast percent
>
Default:
10
Options:
0 to 255
Definition:
The percentage value that sets the adaptive threshold map. Useful for
underprinted or overprinted symbols.
For example, if a value of 110 is entered, the adaptive threshold will be
110% of the original values.
Serial Cmd:
<
K512,
threshold mode,fixed threshold value,cycle min,cycle max,cycle
step,
adaptive contrast percent
>
Default:
100
Options:
1 to 200
Содержание Quadrus MINI
Страница 1: ...Quadrus MINI Imager User s Manual P N 83 006300 Rev H...
Страница 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Страница 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Страница 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Страница 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Страница 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Страница 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Страница 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Страница 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Страница 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...
Страница 424: ...26 Quadrus MINI Imager User s Manual Y...