Quadrus MINI Imager User’s Manual
7-7
I/O Parameters
No Read Message
No Read Message Mode
Disabled
Only symbol data is output after a read cycle.
Enabled
When the imager is in a triggered mode, a No Read message will be appended for each
failed read attempt.
Detailed No Read Message
Important: In the case where the conditions set in Bad Symbol/No Symbol Qualification
are met, then the Bad Symbol or No Symbol message output will override the No Read
Message or the Detailed No Read Message, if either is enabled.
Note: Detailed No Read Message is not supported when Q-Mode is enabled.
For example, in the following output: “No Read d_1, E_2”, d and E are symbology i.d.s for
Data Matrix and UPC respectively. The message means that Data Matrix and UPC are
enabled (and other symbologies are not), and that both failed to decode. The reason for
the failing Data Matrix is 1 and the reason for the failing UPC is 2. The first part of these
numbers (preceding the dot) is the relevant number and is interpreted here:
2D Symbols:
1. Failed to locate symbol (no finder pattern).
2. Failed to locate four corners or failed to qualify user defined dimensions (in pixels).
3. Failed to locate clock patterns or failed to qualify user defined orientation (0-359
degree).
4. Failed to validate clock patterns or failed to qualify user defined symbol size (clock
element count).
5. Failed to decode symbol.
Usage:
Used in applications where the host needs serial verification that a symbol
has not been read and especially useful in new print verification.
Definition:
When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No Read message will be transmitted to the host.
Serial Cmd:
<
K714,No Read message status
,No Read message
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
2 = Detailed No Read Message
Usage:
Use this option to cover more detailed reasons for decode failures.
Definition:
Outputs a No Read message followed by an additional message (an
Image Processing Results Code) indicating the reason a symbol failed to
decode.
Содержание Quadrus MINI
Страница 1: ...Quadrus MINI Imager User s Manual P N 83 006300 Rev H...
Страница 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Страница 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Страница 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Страница 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Страница 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Страница 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Страница 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Страница 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Страница 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...
Страница 424: ...26 Quadrus MINI Imager User s Manual Y...