Quadrus MINI Imager User’s Manual
6-27
Symbologies
Pharmacode
Fixed Symbol Length Status (Pharmacode)
Fixed Symbol Length (Pharmacode)
Minimum Number of Bars (Pharmacode)
Usage:
Used mostly with packaging for the pharmaceuticals industry.
Definition:
Encodes up to five different numbers, each with its own color, which may
be entered in decimal or “binary” format with a 1 represented by a thick bar
and a 0 represented by a thin bar. Bar width is independent of height.
In decimal format, each part can be up to 999,999.
In binary format, each input can have up to 19 ones and zeros.
Important: When Pharmacode is enabled, other linear symbologies will not
decode properly. Disable Pharmacode before reading other linear symbologies.
Serial Cmd:
<
K477,status
,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
When enabled, the imager will check the symbol length against the symbol
length field. If disabled, any length will be considered valid.
Serial Cmd:
<
K477,
status,
fixed symbol length status
,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Specifies the exact number of bars that must be present for the imager to
recognize and decode the Pharmacode symbol.
Serial Cmd:
<
K477,
status,fixed symbol length status,
fixed symbol length
,minimum
number of bars,bar width status,direction,fixed threshold value
>
Default:
5
Options:
1 to 16
Definition:
Sets the minimum number of bars that a Pharmacode symbol must have to
be considered valid.
Note: When Q-Mode is enabled, the minimum allowed bar count is 4.
Serial Cmd:
<
K477,
status,fixed symbol length status,fixed symbol length,
minimum
number of bars
,bar width status,direction,fixed threshold value
>
Default:
2
Options:
1 to 16
4 to 16 (Q-Mode)
Содержание Quadrus MINI
Страница 1: ...Quadrus MINI Imager User s Manual P N 83 006300 Rev H...
Страница 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Страница 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Страница 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Страница 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Страница 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Страница 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Страница 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Страница 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Страница 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...
Страница 424: ...26 Quadrus MINI Imager User s Manual Y...