Symbologies
MS-860 Industrial Raster Reader User’s Manual
9-9
Application Record Separator Status
Note: Output Format must be set to Application Record before this parameter can
take effect.
Note: When set to Disable, app rec sep char is forced to NUL. When set to Enabled,
Application Record Separator Character must also be sent in the same command.
Application Record Separator Character
Note: Application Record Separator Character Status is enabled by setting the
parameter to any value other than a null.
Note: Has no effect unless Application Record Separator Status is enabled.
Application Record Brackets
Note: Output Format must be set to Application Record before this parameter can
take effect.
Definition:
When enabled, a separator character is inserted between application
records.
Serial Cmd:
<
K474,
status,fixed symbol length status,fixed symbol length,EAN-128 sta-
tus,output format,
application record separator status,
application record
separator character,application record brackets,application record padding>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Allows the user to define an ASCII character as an application record sep-
arator.
Serial Cmd:
<
K474,
status,fixed symbol length status,fixed symbol length,EAN-128
status,output format,application record separator status,
application
record separator character
,application record brackets,application
record padding>
Default:
,
(comma)
Options:
User Defined ASCII character
Definition:
When enabled, parentheses ( ) are added to enclose application identifi-
ers.
Serial Cmd:
<
K474,
status,fixed symbol length status,fixed symbol length,EAN-128
status,output format,application record separator status,application
record separator character
,application record brackets
,
application
record padding>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com