EZ Mode
2-2
MS-860 Industrial Raster Reader User’s Manual
EZ Mode
In
EZ Mode you are presented with the
Test
option and, if appropriate for your appli-
cation,
Calibration. After connecting to your reader (or reader) the Setup Mode will
first appear. This will provide you with instructions specific to your model that will help
you in positioning, testing, and if appropriate, calibrating.
Test
Click the
Test
button
to start the read rate test for a quick indication of the read capa-
bilities and the limits of your application. When
Decodes per Second is unchecked,
the test will count the percentage of decodes relative to the number of actual scans.
Click
Stop
to end the test.
Calibrate
Some models include a calibration routine that will optimize reads by comparing read
rates at various settings in focal lengths, scan speeds, and gain settings.
Note: This view may be
slightly different for each
model.
Test Button
Click here to change
from percentage of
good decodes to
decodes per second
Calibration is available
on some models
Saves Calibration
results (if available)
Ends the read rate test
On some models, clicking Autodiscriminate will
enable most available symbology types.